MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3724/sp.j.1123.2014.01035

Медицинская библиотека · Se pu = Chinese journal of chromatography · 2014

[Determination of five representative ultraviolet filters in water by gas chromatography-mass spectrometry].

Ding Yiran, Huang Yun, Zhao Tingting, Cai Qian, Luo Yu, Huang Bin, Zhang Yuxia, Pan Xuejun

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

A method for the determination of five representative organic UV filters: ethylhexyl methoxycinnamate (EHMC), benzophenone-3 (BP-3), 4-methylbenzylidene camphor (4-MBC), octocrylene (OC), homosalate (HMS) in water was investigated. The method was ased on derivatization, solid phase extraction (SPE), followed by determination with gas chromatography-mass spectrometry (GC-MS). The variables involved in the derivatization of BP-3 and HMS were optimized, and SPE conditions were studied. For derivatization, 100 microL N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) was used as derivatization reagent and reacted with BP-3 and HMS at 100 degrees C for 100 min. For SPE, the pH value of water sample was adjusted to 3-5. The Oasis HLB cartridges were employed and the solution of ethyl acetate and dichloromethane (1 : 1, v/v) was used as the eluting solvent, and good recoveries of the target compounds were obtained. The limits of detection (LODs) and the limits of quantification (LOQs) for the five target compounds in water samples were 0.5-1.2 ng/L and 1.4-4.0 ng/L, respectively. The recoveries of spiked water samples were 87.85%-102.34% with good repeatability and reproducibility (RSD < 5%, n = 3) for all the target compounds. Finally, the validated method was applied to analysis the representative UV filters in water samples collected from a wastewater treatment plant in Kunming city of Yunnan province.

Для цитирования: Ding Yiran, Huang Yun, Zhao Tingting, Cai Qian, Luo Yu, Huang Bin, Zhang Yuxia, Pan Xuejun. [Determination of five representative ultraviolet filters in water by gas chromatography-mass spectrometry].. Se pu = Chinese journal of chromatography. 2014. DOI: 10.3724/sp.j.1123.2014.01035.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.