Safety and bleeding profile of continuous levonorgestrel 90 mcg/ethinyl estradiol 20 mcg based on 2 years of clinical trial data in Canada.

Reid Robert L, Fortier Michel P, Smith Lynne, Mirkin Sebastian, Grubb Gary S, Constantine Ginger D

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The study was conducted to evaluate bleeding profile and safety of continuous oral contraceptive (OC) containing levonorgestrel (LNG) 90 mcg/ethinyl estradiol (EE) 20 mcg.

STUDY

DESIGN

Healthy women who participated at seven Canadian sites in 1-year open-label study of LNG 90 mcg/EE 20 mcg daily were eligible for this second-year extension study. Primary end points included bleeding profile and adverse events.

RESULTS

Seventy-nine women enrolled without interrupting pill taking; 62 (78.5%) completed. Adverse events were comparable to cyclic OC regimens, except unscheduled vaginal bleeding. Amenorrhea and absence of bleeding increased to about 80% and 90%, respectively, by Pill Pack 18. Mean (median) number of bleeding days for the last two 90-day intervals was 1.1 (0) and 0.7 (0) days, respectively.

CONCLUSIONS

Continuous LNG 90 mcg/EE 20 mcg had a safety profile similar to low-dose cyclic OCs. Short-term safety profile remained excellent, with increasing rates of amenorrhea and decreasing incidence of unscheduled bleeding and/or spotting.

Для цитирования: Reid Robert L, Fortier Michel P, Smith Lynne, Mirkin Sebastian, Grubb Gary S, Constantine Ginger D. Safety and bleeding profile of continuous levonorgestrel 90 mcg/ethinyl estradiol 20 mcg based on 2 years of clinical trial data in Canada.. Contraception. 2010. DOI: 10.1016/j.contraception.2010.06.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.