MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-010-1203-3

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2010

The low-profile Roman bridge technique for knotless double-row repair of the rotator cuff.

Longo Umile Giuseppe, Franceschi Francesco, Spiezia Filippo, Marinozzi Andrea, Maffulli Nicola, Denaro Vincenzo

СтатьяПеревод в очереди

Аннотация

With advances in arthroscopic surgery, many techniques have been developed to increase the tendon-bone contact area, reconstituting a more anatomic configuration of the rotator cuff footprint and providing a better environment for tendon healing. We present a low-profile arthroscopic rotator cuff repair technique which uses suture bridges to optimize rotator cuff tendon-footprint contact area and mean pressure. A 5.5 mm Bio-Corkscrew suture anchor (Arthrex, Naples, FL, USA), double-loaded with No. 2 FiberWire sutures (Arthrex, Naples, FL, USA), is placed in the anteromedial aspect of the footprint. Two suture limbs from a single suture are both passed through a single anterior point in the rotator cuff. One suture limb is retrieved from the cannula. The second suture limb is passed through a single posterior point in the rotator cuff producing two points of fixation in the tendon, with a tendon bridge between them. The same suture limb is retrieved through the lateral portal, and then inserted into the bone by means of a Pushlock (Arthrex, Naples, FL, USA), placed approximately 1.5-2 cm posterior to the first anchor. This second suture is passed again in the posterior aspect of the cuff. The limbs of the first suture are pulled to compress the tendon in the medial aspect of the footprint. The two free suture limbs are used to produce suture bridges over the tendon by means of a Pushlock (Arthrex, Naples, FL, USA), placed 1 cm distal to the lateral edge of the footprint relative to the medially placed suture anchors anterior to posterior. This technique allows us to perform a low-profile (single pulley-suture bridges) repair for knotless double-row repair of the rotator cuff.

Для цитирования: Longo Umile Giuseppe, Franceschi Francesco, Spiezia Filippo, Marinozzi Andrea, Maffulli Nicola, Denaro Vincenzo. The low-profile Roman bridge technique for knotless double-row repair of the rotator cuff.. Archives of orthopaedic and trauma surgery. 2010. DOI: 10.1007/s00402-010-1203-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.