MedElevator Войти в исследования
← Поиск публикаций

DOI 10.24875/gmm.20005675

Медицинская библиотека · Gaceta medica de Mexico · 2020

Design, manufacture and initial tests of a drug-eluting coronary stent.

Abundes-Velasco Arturo, Padilla-Ibarra Jorge, Jiménez-Rodríguez Gian M, Farjat-Pasos Julio I, Arias-Sánchez Eduardo A, Santos Félix Damas-de Los, Martínez-Ríos Marco A, Molina-Méndez Francisco J, Sánchez-Pérez Tomás E, Arai-Ito Marco M, González Sebastián Aceves-Díaz, Rodríguez-Parra David A, Aranda-Fraustro Alberto, Masso-Rojas Felipe A, Galaz-Méndez Ramsés, Peña-Duque Marco A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease.

OBJECTIVE

To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs' antiproliferative activity and histological results.

METHOD: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models.

RESULTS

Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols.

CONCLUSIONS

Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.

Для цитирования: Abundes-Velasco Arturo, Padilla-Ibarra Jorge, Jiménez-Rodríguez Gian M, Farjat-Pasos Julio I, Arias-Sánchez Eduardo A, Santos Félix Damas-de Los, Martínez-Ríos Marco A, Molina-Méndez Francisco J, Sánchez-Pérez Tomás E, Arai-Ito Marco M, González Sebastián Aceves-Díaz, Rodríguez-Parra David A, Aranda-Fraustro Alberto, Masso-Rojas Felipe A, Galaz-Méndez Ramsés, Peña-Duque Marco A. Design, manufacture and initial tests of a drug-eluting coronary stent.. Gaceta medica de Mexico. 2020. DOI: 10.24875/gmm.20005675.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.