Journal of chiropractic medicine · 2022
Comparison of the Effect of Osteopathic Manipulations and Exercises on the Myoelectric Activity of the Pelvic Floor: A Randomized Controlled Trial.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Arcanjo Giselle Notini, Pires Juliana Lerche Vieira Rocha, Jacinto Maria Edna Mateus, Colares Josué Magalhães, Belo Lurdyanne Maria Cavalcante, Lima Pedro Olavo de Paula, Vilaça-Alves José
Аннотация
OBJECTIVE: The purpose of this clinical trial was to compare the effects of 4 different interventions on electromyographic activity of the pelvic floor muscles in women with stress urinary incontinence (UI).
METHODS: Fifty-one women with stress UI were randomized into 4 groups: a global osteopathic protocol (myofascial, visceral, and articular techniques); 1 manipulation technique (high-velocity, low-amplitude/thrust) of the sacroiliac joint and T10-L2; training of the pelvic floor muscles; and no intervention (control). Electromyographic activity of the pelvic floor muscles was evaluated at 5 different times (baseline, immediately after the procedure, 30 minutes, 1 hour, and 4 weeks after intervention).
RESULTS: Forty women completed the study. There were no immediate or late effects on the myoelectric activity of any type of muscle fiber in any of the groups analyzed.
CONCLUSION: There were no significant between-groups differences of electromyography in women with symptoms of stress UI.
METHODS: Fifty-one women with stress UI were randomized into 4 groups: a global osteopathic protocol (myofascial, visceral, and articular techniques); 1 manipulation technique (high-velocity, low-amplitude/thrust) of the sacroiliac joint and T10-L2; training of the pelvic floor muscles; and no intervention (control). Electromyographic activity of the pelvic floor muscles was evaluated at 5 different times (baseline, immediately after the procedure, 30 minutes, 1 hour, and 4 weeks after intervention).
RESULTS: Forty women completed the study. There were no immediate or late effects on the myoelectric activity of any type of muscle fiber in any of the groups analyzed.
CONCLUSION: There were no significant between-groups differences of electromyography in women with symptoms of stress UI.