m+Medelevator.RU
← Поиск публикаций
Cardiology in the young · 2019

Near-infrared spectroscopy for prediction of extubation success after neonatal cardiac surgery.

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gradidge Eleanor A, Grimaldi Lisa M, Cashen Katherine, Gowda Keshava M N, Piggott Kurt D, Wilhelm Michael, Costello John M, Mastropietro Christopher W

Аннотация

INTRODUCTION: Reliable predictors of extubation readiness are needed and may reduce morbidity related to extubation failure. We aimed to examine the relationship between changes in pre-extubation near-infrared spectroscopy measurements from baseline and extubation outcomes after neonatal cardiac surgery.

MATERIALS AND METHODS: In this retrospective cross-sectional multi-centre study, a secondary analysis of prospectively collected data from neonates who underwent cardiac surgery at seven tertiary-care children's hospitals in 2015 was performed. Extubation failure was defined as need for re-intubation within 72 hours of the first planned extubation attempt. Near-infrared spectroscopy measurements obtained before surgery and before extubation in patients who failed extubation were compared to those of patients who extubated successfully using t-tests.

RESULTS: Near-infrared spectroscopy measurements were available for 159 neonates, including 52 with single ventricle physiology. Median age at surgery was 6 days (range: 1-29 days). A total of 15 patients (9.4 %) failed extubation. Baseline cerebral and renal near-infrared spectroscopy measurements were not statistically different between those who were successfully extubated and those who failed, but pre-extubation cerebral and renal values were significantly higher in neonates who extubated successfully. An increase from baseline to time of extubation values in cerebral oximetry saturation by ≥ 5 % had a positive predictive value for extubation success of 98.6 % (95%CI: 91.1-99.8 %).

CONCLUSION: Pre-extubation cerebral near-infrared spectroscopy measurements, when compared to baseline, were significantly associated with extubation outcomes. These findings demonstrate the potential of this tool as a valuable adjunct in assessing extubation readiness after paediatric cardiac surgery and warrant further evaluation in a larger prospective study.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты