m+Medelevator.RU
← Поиск публикаций
Acta radiologica (Stockholm, Sweden : 1987) · 2025

Assessing the aggressiveness of prostate cancer using ADC and relaxation maps from synthetic MRI.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sirolu Sabri, Seker Mustafa Ege, Alis Deniz, Guroz Batuhan, Kayhan Cavit Kerem, Tokat Fatma, Argun Omer Burak, Oksuz Ilkay, Karaarslan Ercan

Аннотация

BackgroundEmerging evidence suggests multiparametric prostate MRI's role in evaluating prostate cancer (PCa) aggressiveness.PurposeTo evaluate the utility of quantitative sequences in prostate MRI for assessing peripheral zone PCa aggressiveness, focusing on added value of relaxation maps to ADC.Material and MethodsIn total, 64 men undergoing preoperative bi-parametric prostate MRI with synthetic sequences were retrospectively enrolled. Radiologists delineated lesions on ADC maps and synthetic MRI, matched with digitized whole-mount specimens. PCa was graded as low, intermediate, or high based on Gleason grade. Statistical analyses assessed differences in T1, T2, PD, and ADC values across grades. For significant variables, AUC curves were generated. A logistic regression model evaluated the added diagnostic value of relaxation maps to ADC.ResultsOf the 95 PCa foci, 11 were low-grade, 45 intermediate-grade, and 39 high-grade. T1 (P = 0.4) and PD (P = 0.3) showed no significant differences, while T2 and ADC differed significantly (P < 0.001). Median T2 values were 98 ms (low-grade), 81 ms (intermediate), and 73 ms (high-grade), and median ADC values were 1006 mm²/s, 836 mm²/s, and 721 mm²/s, respectively. ADC yielded AUCs of 0.888 (95% CI=0.794-0.963; P < 0.0001) for low- versus intermediate-to-high-grade PCa, and 0.825 (95% CI=0.724-0.901; P < 0.0001) for low-to-intermediate versus high-grade. T2 AUCs were 0.770 (95% CI=0.605-0.908; P = 0.021) and 0.755 (95% CI=0.648-0.864; P = 0.0051), respectively. A logistic regression model combining T2 and ADC showed no significant improvement over ADC alone in differentiating low- versus intermediate-to-high-grade and low-to-intermediate versus high-grade PCa (P > 0.05).ConclusionT1 and PD maps from synthetic MRI showed limited utility in grading PCa. Although T2 values were effective, ADC values were superior in assessing PCa aggressiveness. The addition of T2 to ADC did not significantly improve diagnostic performance.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты