MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2008.10.015

Медицинская библиотека · Biosensors & bioelectronics · 2008

Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip.

Chen Wei, Peng Chifang, Jin Zhengyue, Qiao Ruirui, Wang Wuyang, Zhu Shuifang, Wang Libing, Jin Qinhui, Xu Chuanlai

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The present paper described a rapid and ultrasensitive detection method using a microfluidic chip for analyzing 7-aminoclonazepam (7-ACZP) residues in human urine. A microfluidic chip-based immunoassay with laser-induced fluorescence (LIF) detection based on the water-soluble denatured bovine serum albumin (dBSA)-coated CdTe quantum dots (QDs) was prepared for the ultrasensitive detection of 7-ACZP. The whole procedure including the chip and the control software was designed and constructed in our own laboratory. The detection of 7-ACZP could be completed within 5 min. The results demonstrated that under the optima conditions, 7-ACZP residues could be detected with a precision of 5% relative standard deviation (RSD), and the linear range and the limit of detection (LOD) for 7-ACZP were 1.1-60.1 and 0.021 ngmL(-1), respectively. This method was compared with ELISA and showed a good correlation. This microfluidic chip with LIF detection was applied to the determination of 7-ACZP residues in positive human urine samples, and the results were confirmed by high-performance liquid chromatography and tandem mass spectrometry (LC/MS/MS). This ultrasensitive detection technique was proved to be practical for clinical use.

Для цитирования: Chen Wei, Peng Chifang, Jin Zhengyue, Qiao Ruirui, Wang Wuyang, Zhu Shuifang, Wang Libing, Jin Qinhui, Xu Chuanlai. Ultrasensitive immunoassay of 7-aminoclonazepam in human urine based on CdTe nanoparticle bioconjugations by fabricated microfluidic chip.. Biosensors & bioelectronics. 2008. DOI: 10.1016/j.bios.2008.10.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.