MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2015.08.066

Медицинская библиотека · Journal of chromatography. A · 2015

Analysis of diarrhetic shellfish poisoning toxins and pectenotoxin-2 in the bottlenose dolphin (Tursiops truncatus) by liquid chromatography-tandem mass spectrometry.

Wang Zhihong, Broadwater Margaret H, Ramsdell John S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Toxins produced by harmful algae are associated with detrimental health effects and mass mortalities of marine mammals. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is generally used to confirm the presence of algal toxins in marine mammals. Sample preparation and LC-MS/MS methods for the determination of three diarrhetic shellfish poisoning (DSP) toxins (okadaic acid, OA; dinophysistoxin-1, DTX1; dinophysistoxin-2, DTX2) and pectenotoxin-2 (PTX2) in bottlenose dolphin (Tursiops truncatus) urine and tissue samples were evaluated using spike-and-recovery tests. Sample clean-up with either reversed-phase silica or polymeric solid-phase extraction (SPE) reduced interference of sample matrices and improved toxin recoveries, with polymeric SPE showing higher sample loading capacity. LC separation on Xbridge C18 columns using acetonitrile/water gradient elutions with ammonia as the additive was chosen for its high detectivity and sensitivity in the MS detection of DSP toxins in negative ion mode. The retention times of OA, DTX1, and DTX2, separated as negative ions, increased with LC column temperature while the retention time of PTX2, separated as the neutral molecule, was weakly affected. At the same column temperature, retention times of OA, DTX1, and DTX2 gradually increased as the mobile phases aged while the retention time of PTX2 remained unchanged; higher column temperatures resulted in a greater increase in the retention time of each DSP toxin with mobile phase aging. Average recoveries of the 4 toxins in bottlenose dolphin samples ranged from 80% to 130% with relative standard deviations of less than 15% using the LC mobile phases prepared within one week at a column temperature of 30°C or 40°C. The preferred column temperature was 30°C, as the retention times of DSP toxins were less affected by mobile phase aging at this temperature. The limit of detection of each toxin analyzed in bottlenose dolphin samples was 2.8 ng/g or less in tissue samples and 0.7 ng/ml or less in urine.

Для цитирования: Wang Zhihong, Broadwater Margaret H, Ramsdell John S. Analysis of diarrhetic shellfish poisoning toxins and pectenotoxin-2 in the bottlenose dolphin (Tursiops truncatus) by liquid chromatography-tandem mass spectrometry.. Journal of chromatography. A. 2015. DOI: 10.1016/j.chroma.2015.08.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.