MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2020.03.062

Медицинская библиотека · World neurosurgery · 2020

Low-Cost Stereotactic Brain Biopsy Simulation Model.

Cuello Javier Francisco, Saenz Amparo, Liñares Juan Manuel, Martinez Patricia, Ruiz Carolina, Argañaraz Romina, Bailez María Marcela, Mantese Beatriz

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Simulation training improves technical skills in a safe environment. Stereotactic techniques are widely used in neurosurgery for different kinds of procedures. The objective of the study was to describe a combined cadaveric and synthetic low-cost stereotactic simulation model and its validation by neurosurgeons.

METHODS

The brain was made using self-supporting gel with solid and cystic lesions. We used imaging scans to calculate x, y, and z target coordinates. A standard frame needle biopsy was performed. We calculated the number of mistakes and time needed to accomplish the task, and we evaluated the frame assembly and biopsy performance. Wilcoxon signed rank was used to analyzed the data; we considered a P value <0.05 as statistically significant.

RESULTS

The median initial number of mistakes was 32 (interquartile range [IQR]: 27.5-37) and after repeated training and feedback the final median number was 3.5 (IQR: 2-6) (P < 0.001). The median time needed to finish the exercises before training was 1020.5 seconds (IQR: 908-1125.5) and after using the model the final median time was 479 seconds (IQR: 423-503) (P < 0.0001).

CONCLUSIONS

We presented a stereotactic simulation model with immediate haptic feedback. The model can be easily handmade in any neurosurgical laboratory. This model allows neurosurgeons in training to acquire and improve stereotactic techniques, reducing the number of surgical mistakes and time needed to finish the task.

Для цитирования: Cuello Javier Francisco, Saenz Amparo, Liñares Juan Manuel, Martinez Patricia, Ruiz Carolina, Argañaraz Romina, Bailez María Marcela, Mantese Beatriz. Low-Cost Stereotactic Brain Biopsy Simulation Model.. World neurosurgery. 2020. DOI: 10.1016/j.wneu.2020.03.062.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.