MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13049-021-00891-5

Медицинская библиотека · Scandinavian journal of trauma, resuscitation and emergency medicine · 2021

Diagnostic accuracy of prehospital serum S100B and GFAP in patients with mild traumatic brain injury: a prospective observational multicenter cohort study - "the PreTBI I study".

Seidenfaden Sophie-Charlott, Kjerulff Julie Linding, Juul Niels, Kirkegaard Hans, Møller Mette Fogh, Münster Anna-Marie Bloch, Bøtker Morten Thingemann

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The biomarker serum S100 calcium-binding protein B (S100B) is used in in-hospital triage of adults with mild traumatic brain injury to rule out intracranial lesions. The biomarker glial fibrillary acidic protein (GFAP) is suggested as a potential diagnostic biomarker for traumatic brain injury. The aim of this study was to investigate the diagnostic accuracy of early prehospital S100B and GFAP measurements to rule out intracranial lesions in adult patients with mild traumatic brain injury.

METHODS

Prehospital and in-hospital blood samples were drawn from 566 adult patients with mild traumatic brain injury (Glasgow Coma Scale Score 14-15). The index test was S100B and GFAP concentrations. The reference standard was endpoint adjudication of the traumatic intracranial lesion based on medical records. The primary outcome was prehospital sensitivity of S100B in relation to the traumatic intracranial lesion.

RESULTS

Traumatic intracranial lesions were found in 32/566 (5.6%) patients. The sensitivity of S100B > 0.10 μg/L was 100% (95%CI: 89.1;100.0) in prehospital samples and 100% (95% CI 89.1;100.0) in in-hospital samples. The specificity was 15.4% (95%CI: 12.4;18.7) in prehospital samples and 31.5% (27.5;35.6) in in-hospital samples. GFAP was only detected in less than 2% of cases with the assay used.

CONCLUSION

Early prehospital and in-hospital S100B levels < 0.10 μg/L safely rules out traumatic intracranial lesions in adult patients with mild traumatic brain injury, but specificity is lower with early prehospital sampling than with in-hospital sampling. The very limited cases with values detectable with our assay do not allow conclusions to be draw regarding the diagnostic accuracy of GFAP.

TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02867137 .

Для цитирования: Seidenfaden Sophie-Charlott, Kjerulff Julie Linding, Juul Niels, Kirkegaard Hans, Møller Mette Fogh, Münster Anna-Marie Bloch, Bøtker Morten Thingemann. Diagnostic accuracy of prehospital serum S100B and GFAP in patients with mild traumatic brain injury: a prospective observational multicenter cohort study - "the PreTBI I study".. Scandinavian journal of trauma, resuscitation and emergency medicine. 2021. DOI: 10.1186/s13049-021-00891-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.