MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/ac902902y

Медицинская библиотека · Analytical chemistry · 2010

Dynamic labeling strategy with 204Hg-isotopic methylmercurithiosalicylate for absolute peptide and protein quantification.

Xu Ming, Yan Xiaowen, Xie Qingqing, Yang Limin, Wang Qiuquan

Письмо в редакциюПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The methylmercury ion (CH(3)Hg(+)) demonstrated a high efficiency for directly labeling peptide/protein based on its specific and strong interaction with the sulfhydryl(s) in the peptide/protein and because of its smallest size among monofunctional organic mercurials studied, including methylmercury, ethylmercury, 4-(hydroxymercuric)benzoic acid, and 2,7-dibromo-4-hydroxymercurifluoresceine disodium. A simple 1:1 stoichiometry between CH(3)Hg(+) and sulfhydryl, confirmed with electrospray ionization-mass spectrometry (ESI-MS) and matrix-assisted laser desorption ionization-time-of-flight-mass spectrometry (MALDI-TOF-MS) studies, made it easy to calibrate the stoichiometry of Hg in the peptide/protein. In order to avoid the direct use of the harmful CH(3)Hg(+), in this study a CH(3)Hg(+)-equivalent tag, methylmercurithiosalicylate (CH(3)Hg-THI), and its (204)Hg-enriched homologue (CH(3)(204)Hg-THI) were synthesized, and then CH(3)Hg(+) and/or CH(3)(204)Hg(+) released from CH(3)Hg-THI and/or CH(3)(204)Hg-THI in solution were utilized to demonstrate the dynamic labeling of glutathione (GSH) and two model proteins, beta-lactoglobulin (BLG) and ovalbumin (OVA), for the first time. Furthermore, the CH(3)(204)Hg-THI isotopical labeled GSH, BLG, and OVA standards (CH(3)(204)Hg-GSH, CH(3)(204)Hg-BLG, and CH(3)(204)Hg-OVA) were used to demonstrate the feasibility of absolute peptide/protein quantification using label-specific isotope dilution inductively coupled plasma mass spectrometry (ICPMS). On the basis of the accurate and sensitive determination of Hg using ICPMS, the detection limits of GSH, BLG, and OVA could reach 45.4, 45.4, and 15.1 pmol L(-1), respectively, suggesting the possibility for low-abundance peptide/protein quantification alongside the surefire quantification of moderate and highly abundant peptide/protein.

Для цитирования: Xu Ming, Yan Xiaowen, Xie Qingqing, Yang Limin, Wang Qiuquan. Dynamic labeling strategy with 204Hg-isotopic methylmercurithiosalicylate for absolute peptide and protein quantification.. Analytical chemistry. 2010. DOI: 10.1021/ac902902y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.