MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pntd.0007731

Медицинская библиотека · PLoS neglected tropical diseases · 2019

Develop and Field Evolution of Single Tube Nested PCR, SYBRGreen PCR Methods, for the Diagnosis of Leprosy in Paraffin-embedded Formalin Fixed Tissues in Yunnan Province, a Hyper endemic Area of Leprosy in China.

Chen Xiaohua, Xing Yan, He Jun, Tan Fuyue, You Yuangang, Wen Yan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Detection and pathology analysis of Mycobacterium leprae using skin biopsy tissues are essential for leprosy diagnosis and monitoring response to treatment. Although formalin fixation of patient tissues may not be ideal for molecular studies, biopsy samples are the most accessible material from suspected cases. Therefore, clinical molecular laboratories must be able to utilize formalin-fixed, paraffin-embedded (FFPE) material.

OBJECTIVE

To determine the best molecular method for diagnosing and monitoring leprosy in FFPE specimens, we developed a single-tube nested PCR (STNPCR) (131 bp) and SYBRGreen PCR (101 bp) assay using primers for the M. leprae-specific repetitive element (RLEP) gene and evaluated the results compared to those using previously established RLEP primers (372 bp).

METHODS

FFPE biopsy samples obtained from 145 leprosy patients (during or after multidrug therapy (MDT)) and patients with 29 other confounding dermatoses were examined by the bacteria index (BI) and by simple PCR, STNPCR, and SYBRGreen PCR using primers amplifying a 372-bp, 131-bp or 101-bp fragment of RLEP, respectively.

RESULTS

In leprosy patients receiving MDT, STNPCR showed a highest specificity of 100% and a positive predictive value (PPV) of 100%. For multibacillary (MB), paucibacillary (PB) and all leprosy patients, the highest sensitivities were 91.42%, 39.13%, and 67.92%, negative predictive values (NPVs) were 8.57%, 60.36%, and 32.07%, and the highest accuracies were 93.93%, 62.67%, and 74.81%, respectively, higher than the results of SYBRGreen PCR and simple PCR. For post-MDT leprosy patients, SYBRGreen PCR showed the highest sensitivity of 50.0%, highest specificity of 100%, a PPV of 100%, an NPV of 100% and the highest accuracy of 83.72% for MB patients, which were higher than those of STNPCR and simple PCR. STNPCR showed the highest sensitivity of 26.66% and 34.48%, highest specificity of 100% and 100%, a PPV of 100% and 100%, NPV of 72.50% and 60.21%, and highest accuracy of 75.00% and 67.24% for PB and leprosy patients, respectively, higher than those of SYBRGreen PCR and simple PCR.

CONCLUSIONS

These findings suggest that STNPCR or SYBRGreen PCR (131-bp and 101-bp fragment amplification, respectively) for RLEP using FFPE specimens performs better as a diagnostic test and for monitoring response to MDT than does simple PCR based on 372-bp fragment amplification. Additionally, STNPCR showed increased sensitivity for PB diagnosis using FFPE specimens, which can be transferred remotely or retrieved from previous leprosy patients.

Для цитирования: Chen Xiaohua, Xing Yan, He Jun, Tan Fuyue, You Yuangang, Wen Yan. Develop and Field Evolution of Single Tube Nested PCR, SYBRGreen PCR Methods, for the Diagnosis of Leprosy in Paraffin-embedded Formalin Fixed Tissues in Yunnan Province, a Hyper endemic Area of Leprosy in China.. PLoS neglected tropical diseases. 2019. DOI: 10.1371/journal.pntd.0007731.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.