MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jare.2022.10.008

Медицинская библиотека · Journal of advanced research · 2022

An ultrasensitive NIR-IIa' fluorescence-based multiplex immunochromatographic strip test platform for antibiotic residues detection in milk samples.

Zhang Yunyue, Liao Tao, Wang Guoxin, Xu Juan, Wang Mohan, Ren Fazheng, Zhang Hao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Widely used in livestock breeding, residues of antibiotic drugs in milk have become a threat to food safety and human health. Current rapid detection technologies using colorimetric immunochromatographic strip tests (IST) lack the necessary sensitivity for on-site trace monitoring. Fluorescence-based detection in the near-infrared IIa' (NIR-IIa') region (1000 ∼ 1300 nm) has enormous potential due to greatly minimized auto-fluorescence and light scattering.

OBJECTIVES

The aim of this work is to develop an ultrasensitive IST platform using NIR-IIa' fluorescent nanoparticles as labels for multiplex antibiotic residues detection in milk.

METHODS

NIR-IIa' fluorescent nanoparticles were assembled by encapsulating synthesized NIR-IIa' fluorophores into carboxyl - modified polystyrene nanoparticles. The NIR-IIa' nanoparticles were subsequently used as labels in an IST platform to detect sulfonamides, quinolones, and lincomycin simultaneously in milk. A portable fluorescent reader was fabricated to provide on-site detection. To further validate the developed IST platform, the detection was compared with LC-MS/MS in 22 real milk samples.

RESULTS

Fluorescent nanoparticles were synthesized with low energy emission (1030 nm) and large Stokes shift (>250 nm) showing a much higher signal-to-noise ratio compared with fluorophores emitting in the NIR-I region. The developed IST platform yielded a highly sensitive, simultaneous quantification of sulfonamides, quinolones, and lincomycin in milk with detection limits of 46.7, 27.6 and 51.4 pg/mL, respectively, achieving a wide detection range (up to 50 ng/mL). The IST platform showed good accuracy, reproducibility, and specificity with the portable fluorescent reader which could rapidly quantify in 10 s. These results were better than reported immunochromatographic assays using fluorescent labels, and remarkably, showed a higher recognition ability than LC-MS/MS for real samples.

CONCLUSION

The utility of NIR-IIa' fluorescence-based IST platform for the fast, sensitive, and accurate detection of antibiotics in milk was demonstrated, successfully verifying the potential of this platform in detecting trace materials in complex matrices.

Для цитирования: Zhang Yunyue, Liao Tao, Wang Guoxin, Xu Juan, Wang Mohan, Ren Fazheng, Zhang Hao. An ultrasensitive NIR-IIa' fluorescence-based multiplex immunochromatographic strip test platform for antibiotic residues detection in milk samples.. Journal of advanced research. 2022. DOI: 10.1016/j.jare.2022.10.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.