MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00365513.2021.1980901

Медицинская библиотека · Scandinavian journal of clinical and laboratory investigation · 2021

Study of stability and interference for catecholamines and metanephrines, 3-methoxytyramine: key point of an accurate diagnosis for pheochromocytoma and paraganglioma.

Wang Kaijuan, Gao Xiaojing, Zhang Wei, Sun Nian, Xie Lan, Cong Hongying, Guo Yutong, Shi Xiaocui, Zhou Zhou

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Accurate diagnosis of pheochromocytoma and paraganglioma (PPGLs) is highly dependent on the detection of metanephrines and catecholamines. However, the systematic investigation on influencing factors including specimen (plasma or whole blood), anticoagulant, storage conditions, and interference factors need further confirmation.

METHODS

Blood with heparin-lithium or EDTA-K2 were collected, stability of epinephrine (EPI), norepinephrine (NE), dopamine (DA), metanephrine (MN), normetanephrine (NMN), 3-methoxytyramine (3-MT) in whole blood and plasma at room temperature and 4 °C for different storage times, stability of plasma MN, NMN and 3-MT at -20 °C and -80 °C were investigated. Plasma with hemoglobin (1 g/L, 2 g/L, 3 g/L, 4 g/L, 6 g/L), TG (<5 mmol/L, 5-8 mmol/L, >8 mmol/L) were prepared.

RESULTS

EPI, NE, DA were prone to degrade at room temperature, samples should be centrifuged at 4 °C. EPI and NE were stable in whole blood at 4 °C for 4 h and in plasma for 2 h. For MN, NMN, 3-MT, plasma can be stable at room temperature and 4 °C for at least 6 h, which is better than whole blood; there was no significant difference when stored at -20 °C and -80 °C for 7 days. Heparin-lithium had a slight advantage over EDTA-K2. EPI, NE, DA should not be performed when Hb > 1 g/L or TG > 5 mmol/L. MN, NMN, 3-MT should not be performed when Hb > 2 g/L, whereas TG had no interference.

CONCLUSIONS

According to the actual clinical application scenario, this study provided a reliable basis for the accurate diagnosis of PPGLs.

Для цитирования: Wang Kaijuan, Gao Xiaojing, Zhang Wei, Sun Nian, Xie Lan, Cong Hongying, Guo Yutong, Shi Xiaocui, Zhou Zhou. Study of stability and interference for catecholamines and metanephrines, 3-methoxytyramine: key point of an accurate diagnosis for pheochromocytoma and paraganglioma.. Scandinavian journal of clinical and laboratory investigation. 2021. DOI: 10.1080/00365513.2021.1980901.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.