MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.dld.2023.07.032

Медицинская библиотека · Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver · 2023

Efficacy of 1 L polyethylene glycol plus ascorbate versus 4 L polyethylene glycol in split-dose for colonoscopy cleansing in out and inpatient: A multicentre, randomized trial (OVER 2019).

Vassallo Roberto, Maida Marcello, Zullo Angelo, Venezia Ludovica, Montalbano Luigi, Mitri Roberto Di, Peralta Marco, Virgilio Clara, Pallio Socrate, Pluchino Dario, D'amore Fabio, Santagati Alessio, Sinagra Emanuele, Graceffa Pietro, Nicosia Giuseppe, Camilleri Salvatore, Gibiliaro Gerlando, Abdelhadi Yasmin, Rancatore Gabriele, Scalisi Giuseppe, Melita Giuseppinella, Magnano Antonio, Conoscenti Giuseppe, Facciorusso Antonio, AIGO

Рандомизированное исследованиеМногоцентровое исследованиеСтатьяEquivalence TrialПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Adequate bowel cleansing is essential for colonoscopy quality. A novel 1 L polyethylene glycol plus ascorbate (1 L PEG+ASC) solution has been recently introduced. Nevertheless, the efficacy of 1 L PEG+ASC as compared to that of high-volume bowel preparation in both inpatients and outpatients is still unclear.

PATIENTS AND

METHODS

This single-blinded, non-inferiority study randomized patients undergoing colonoscopy to receive split-dose 1 L PEG+ASC or 4 L PEG. The primary endpoint was the overall cleansing success. Secondary endpoints were excellent cleansing and high-quality cleansing of the right colon, as well as lesions detection rate, patient compliance, tolerability and safety.

RESULTS

Overall, 478 patients were randomized to 1 L PEG+ASC (N = 236) or 4 L PEG (N = 242). The 1 L PEG+ASC showed higher cleansing success rate (91.8% vs 83.6%; P=0.01) and a high-quality cleansing of the right colon (52.3% and 38.5%; P=0.004) compared to 4 L PEG. Moreover, 1 L PEG+ASC achieved a higher cleansing success in out-patients (96.3%% vs 88.6%; P=0.018), and a similar success rate in the in-patients (84.7% vs 76.7%; P=0.18). Adenoma detection rate, tolerability and incidence of adverse events were comparable between preparations.

CONCLUSIONS

The 1 L PEG+ASC showed higher efficacy in achieving adequate colon cleansing compared with 4 L PEG, particularly in the right colon. No differences in the tolerability and safety were detected.

Для цитирования: Vassallo Roberto, Maida Marcello, Zullo Angelo, Venezia Ludovica, Montalbano Luigi, Mitri Roberto Di, Peralta Marco, Virgilio Clara, Pallio Socrate, Pluchino Dario, D'amore Fabio, Santagati Alessio, Sinagra Emanuele, Graceffa Pietro, Nicosia Giuseppe, Camilleri Salvatore, Gibiliaro Gerlando, Abdelhadi Yasmin, Rancatore Gabriele, Scalisi Giuseppe, Melita Giuseppinella, Magnano Antonio, Conoscenti Giuseppe, Facciorusso Antonio, AIGO. Efficacy of 1 L polyethylene glycol plus ascorbate versus 4 L polyethylene glycol in split-dose for colonoscopy cleansing in out and inpatient: A multicentre, randomized trial (OVER 2019).. Digestive and liver disease : official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver. 2023. DOI: 10.1016/j.dld.2023.07.032.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.