INTRODUCTION

This study aimed to analyze the correlation between blood pressure variability (BPV), crystalloid osmotic pressure, and cardiovascular events (CEs) in patients undergoing maintenance hemodialysis (MHD).

METHODS

This retrospective analysis was conducted on 71 patients with end-stage kidney disease who underwent hemodialysis at Beilun District People's Hospital from September 2021 to September 2022. The patients were divided into two groups based on the occurrence of CEs: a cardiovascular event group and a non-cardiovascular event group.

RESULTS

The 71 patients were divided into two groups based on the occurrence of CEs: the CEs group (25 patients who experienced CEs) and the non-CEs group (46 patients who did not experience CEs). The CEs group had significantly higher levels of crystalloid osmotic pressure, standard deviation of systolic BP (SBP-SD), coefficient of variation of SBP (SBP-CV), SD of diastolic BP (DBP-SD), and DBP-CV (P < .05). Multivariate logistic regression analysis identified crystalloid osmotic pressure, SBP-CV, and DBP-CV as independent risk factors for CEs. The ROC curve analysis indicated that the combined predictive value of crystalloid osmotic pressure, SBP-CV, and DBP-CV was significant, with an area under the curve (AUC) of 0.963.

Для цитирования: Chen Tanqi, Cao Shengsheng, Shen Lingzhi, Liu Zhong. Correlation Analysis of Blood Pressure Variability, Crystalloid Osmotic Pressure, and Cardiovascular Events in Maintenance Hemodialysis Patients.. Iranian journal of kidney diseases. 2024. DOI: 10.52547/ijkd.8172.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.