MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10286-019-00606-y

Медицинская библиотека · Clinical autonomic research : official journal of the Clinical Autonomic Research Society · 2019

A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring.

Finucane Ciarán, van Wijnen V K, Fan C W, Soraghan C, Byrne L, Westerhof B E, Freeman R, Fedorowski A, Harms M P M, Wieling W, Kenny R

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

PURPOSE: The average adult stands approximately 50-60 times per day. Cardiovascular responses evoked during the first 3 min of active standing provide a simple means to clinically assess short-term neural and cardiovascular function across the lifespan. Clinically, this response is used to identify the haemodynamic correlates of patient symptoms and attributable causes of (pre-)syncope, and to detect autonomic dysfunction, variants of orthostatic hypotension, postural orthostatic tachycardia syndrome and orthostatic hypertension.

METHODS

This paper provides a set of experience/expertise-based recommendations detailing current state-of-the-art measurement and analysis approaches for the active stand test, focusing on beat-to-beat BP technologies. This information is targeted at those interested in performing and interpreting the active stand test to current international standards.

RESULTS

This paper presents a practical step-by-step guide on (1) how to perform active stand measurements using beat-to-beat continuous blood pressure measurement technologies, (2) how to conduct an analysis of the active stand response and (3) how to identify the spectrum of abnormal blood pressure and heart rate responses which are of clinical interest.

CONCLUSION

Impairments in neurocardiovascular control are an attributable cause of falls and syncope across the lifespan. The simple active stand test provides the clinician with a powerful tool for assessing individuals at risk of such common disorders. However, its simplicity belies the complexity of its interpretation. Care must therefore be taken in administering and interpreting the test in order to maximise its clinical benefit and minimise its misinterpretation.

Для цитирования: Finucane Ciarán, van Wijnen V K, Fan C W, Soraghan C, Byrne L, Westerhof B E, Freeman R, Fedorowski A, Harms M P M, Wieling W, Kenny R. A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring.. Clinical autonomic research : official journal of the Clinical Autonomic Research Society. 2019. DOI: 10.1007/s10286-019-00606-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.