MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13054-022-04060-7

Медицинская библиотека · Critical care (London, England) · 2022

An updated HACOR score for predicting the failure of noninvasive ventilation: a multicenter prospective observational study.

Duan Jun, Chen Lijuan, Liu Xiaoyi, Bozbay Suha, Liu Yuliang, Wang Ke, Esquinas Antonio M, Shu Weiwei, Yang Fuxun, He Dehua, Chen Qimin, Wei Bilin, Chen Baixu, Li Liucun, Tang Manyun, Yuan Guodan, Ding Fei, Huang Tao, Zhang Zhongxing, Tang ZhiJun, Han Xiaoli, Jiang Lei, Bai Linfu, Hu Wenhui, Zhang Rui, Mina Bushra

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Heart rate, acidosis, consciousness, oxygenation, and respiratory rate (HACOR) have been used to predict noninvasive ventilation (NIV) failure. However, the HACOR score fails to consider baseline data. Here, we aimed to update the HACOR score to take into account baseline data and test its predictive power for NIV failure primarily after 1-2 h of NIV.

METHODS

A multicenter prospective observational study was performed in 18 hospitals in China and Turkey. Patients who received NIV because of hypoxemic respiratory failure were enrolled. In Chongqing, China, 1451 patients were enrolled in the training cohort. Outside of Chongqing, another 728 patients were enrolled in the external validation cohort.

RESULTS

Before NIV, the presence of pneumonia, cardiogenic pulmonary edema, pulmonary ARDS, immunosuppression, or septic shock and the SOFA score were strongly associated with NIV failure. These six variables as baseline data were added to the original HACOR score. The AUCs for predicting NIV failure were 0.85 (95% CI 0.84-0.87) and 0.78 (0.75-0.81) tested with the updated HACOR score assessed after 1-2 h of NIV in the training and validation cohorts, respectively. A higher AUC was observed when it was tested with the updated HACOR score compared to the original HACOR score in the training cohort (0.85 vs. 0.80, 0.86 vs. 0.81, and 0.85 vs. 0.82 after 1-2, 12, and 24 h of NIV, respectively; all p values < 0.01). Similar results were found in the validation cohort (0.78 vs. 0.71, 0.79 vs. 0.74, and 0.81 vs. 0.76, respectively; all p values < 0.01). When 7, 10.5, and 14 points of the updated HACOR score were used as cutoff values, the probability of NIV failure was 25%, 50%, and 75%, respectively. Among patients with updated HACOR scores of ≤ 7, 7.5-10.5, 11-14, and > 14 after 1-2 h of NIV, the rate of NIV failure was 12.4%, 38.2%, 67.1%, and 83.7%, respectively.

CONCLUSIONS

The updated HACOR score has high predictive power for NIV failure in patients with hypoxemic respiratory failure. It can be used to help in decision-making when NIV is used.

Для цитирования: Duan Jun, Chen Lijuan, Liu Xiaoyi, Bozbay Suha, Liu Yuliang, Wang Ke, Esquinas Antonio M, Shu Weiwei, Yang Fuxun, He Dehua, Chen Qimin, Wei Bilin, Chen Baixu, Li Liucun, Tang Manyun, Yuan Guodan, Ding Fei, Huang Tao, Zhang Zhongxing, Tang ZhiJun, Han Xiaoli, Jiang Lei, Bai Linfu, Hu Wenhui, Zhang Rui, Mina Bushra. An updated HACOR score for predicting the failure of noninvasive ventilation: a multicenter prospective observational study.. Critical care (London, England). 2022. DOI: 10.1186/s13054-022-04060-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.