Continuous Hydrogen Sulfide Gas Monitoring using the PortaSens II Portable Gas Leak Detector Model C16 during Laparoscopic or Robotic Surgery Cannot Be Used Intraoperatively to Detect Bowel Injury.

Endicott Scott, Lockrow Ernest

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To determine the feasibility of measuring hydrogen sulfide (H2S) gas in the insufflated abdomen during laparoscopic surgery after transmural bowel injury as a marker of unrecognized bowel injuries.

DESIGN

This is a feasibility study performed on swine models during a robotic training course. We aimed to determine baseline H2S levels and subsequent elevations in H2S levels after enterotomy of the large and small intestines.

SETTING

University-based robotic training lab.

PARTICIPANTS

Three swine participants.

INTERVENTIONS: During initial insufflation of the swine abdominal cavity, baseline H2S levels were recorded over 15-second intervals for 10 minutes using the PortaSens II Portable Gas Leak Detector Model C16 (Analytical Technology, Inc., Collegeville, PA). The same values were recorded in separate studies after transmural transection of the small intestine and the large intestine using laparoscopic shears with and without monopolar electrosurgery.

MEASUREMENTS AND MAIN

RESULTS

Baseline H2S level over the initial 10 minutes of insufflation was 0 parts per million (ppm). The device is calibrated to detect levels of H2S of 0 ppm to 200 ppm. H2S levels after small and large bowel enterotomies without monopolar electrosurgery initially showed a rise to 1 ppm to 2 ppm. However, repeat confirmatory testing failed to show any elevation in H2S levels. H2S levels after small and large bowel enterotomies with monopolar electrosurgery both showed increases to 108 ppm and 74 ppm with a duration of elevation measuring 4 minutes and 4 minutes 15 seconds, respectively. Although our study did show elevations in H2S after transection with monopolar electrosurgery, this was later determined to be the result of cross contamination with carbon monoxide, which was a confounding factor.

CONCLUSION

Our study demonstrated that using the methodology and detection methods described, H2S cannot be used to detect unrecognized bowel injury during laparoscopic surgery. Our results were due to cross contamination with other gases created with the use of electrosurgery, and we were unable to reproduce initial testing results, which did show slight rises in H2S levels after enterotomies without monopolar electrosurgery. Further testing of other gases produced by the gastrointestinal tract or the use of alternative detection methods may provide more clinically relevant results.

Для цитирования: Endicott Scott, Lockrow Ernest. Continuous Hydrogen Sulfide Gas Monitoring using the PortaSens II Portable Gas Leak Detector Model C16 during Laparoscopic or Robotic Surgery Cannot Be Used Intraoperatively to Detect Bowel Injury.. Journal of minimally invasive gynecology. 2020. DOI: 10.1016/j.jmig.2020.03.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.