MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.rpor.2019.12.020

Медицинская библиотека · Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2019

Optimization of an ultra-fast silicon detector for proton and carbon beams using GEANT4 Monte Carlo toolkit.

Mashayekhi Mohsen, Mowlavi Ali Asghar, Jia Sayyed Bijan, Ghayoumizadeh Hossein

СтатьяПеревод в очереди

Аннотация

AIM: The purpose of this study was to investigate the crosstalk effects between adjacent pixels in a thin silicon detector with 50 um thickness.

BACKGROUND

There are some limitations in the applications of detectors in hadron therapy. So it is necessary to have a detector with concurrent excellent time and resolution. In this work, the GEANT4 toolkit was applied to estimate the best value for energy cutoff in the thin silicon detector in order to optimize the detector.

MATERIALS AND

METHODS

GEANT4 toolkit was applied to simulate the transport and interactions of particles. Calculations were performed for a thin silicon detector (2 cm × 2 cm×0.005 cm) irradiated by proton and carbon ion beams. A two-dimensional array of silicon pixels in the x-y plane with 100 um × 100 um × 50 um dimensions build the whole detector. In the end, the ROOT package is used to interpret and analyze the results.

RESULTS

It is seen that by the presence of energy cutoff, pixels with small deposited energy are ignored. The best values for energy cutoff are 0.01 MeV and 0.7 MeV for proton and carbon ion beams, respectively. By applying these energy cutoff values, efficiency and purity values are maximized and also minimum output errors are achieved.

CONCLUSIONS

The results are reasonable, good and useful to optimize the geometry of future silicon detectors in order to be used as beam monitoring in hadron therapy applications.

Для цитирования: Mashayekhi Mohsen, Mowlavi Ali Asghar, Jia Sayyed Bijan, Ghayoumizadeh Hossein. Optimization of an ultra-fast silicon detector for proton and carbon beams using GEANT4 Monte Carlo toolkit.. Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. 2019. DOI: 10.1016/j.rpor.2019.12.020.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.