Differentiation of heroin and cocaine using dual-energy CT-an experimental study.

Grimm Jochen, Wudy Ramona, Ziegeler Edvard, Wirth Stefan, Uhl Michael, Reiser Maximilian F, Scherr Michael

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate if heroin and cocaine can be distinguished using dual-energy CT.

MATERIALS AND

METHODS

Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation.

RESULTS

Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression.

CONCLUSION

The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.

Для цитирования: Grimm Jochen, Wudy Ramona, Ziegeler Edvard, Wirth Stefan, Uhl Michael, Reiser Maximilian F, Scherr Michael. Differentiation of heroin and cocaine using dual-energy CT-an experimental study.. International journal of legal medicine. 2014. DOI: 10.1007/s00414-014-0980-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.