MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.21786

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2009

Noninvasive in vivo electron paramagnetic resonance study to estimate pulmonary reducing ability in mice exposed to NiO or C60 nanoparticles.

Yokoyama Hidekatsu, Ono Taizo, Morimoto Yasuo, Myojo Toshihiko, Tanaka Isamu, Shimada Manabu, Wang Wei-Ning, Endoh Shigehisa, Uchida Kunio

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To develop new methods that can estimate the influences of manufactured nanomaterials on biological systems, the in vivo pulmonary reducing ability of mice that had received inhalation exposures to NiO or C60 nanoparticles was investigated using a 700 MHz electron paramagnetic resonance (EPR) spectrometer.

MATERIALS AND

METHODS

NiO or C60 suspensions were atomized and mice in exposure chambers inhaled the resulting aerosol particles for 3 hours. The exposure conditions, number-based geometric average diameters, and the average number concentration were precisely controlled at almost the same levels for both NiO and C60 nanoparticles. Two days or 2 weeks after exposure, an EPR study was conducted noninvasively. Temporal changes in EPR signal intensity at the target area (ie, lung field) were obtained by the region-selected intensity determination (RSID) method.

RESULTS

NiO nanoparticles significantly suppressed pulmonary reducing ability 2 days and 2 weeks after exposure, but C60 nanoparticles had no such effect.

CONCLUSION

This is the first in vivo estimation of the reducing ability in experimental animals exposed to manufactured nanoparticles.

Для цитирования: Yokoyama Hidekatsu, Ono Taizo, Morimoto Yasuo, Myojo Toshihiko, Tanaka Isamu, Shimada Manabu, Wang Wei-Ning, Endoh Shigehisa, Uchida Kunio. Noninvasive in vivo electron paramagnetic resonance study to estimate pulmonary reducing ability in mice exposed to NiO or C60 nanoparticles.. Journal of magnetic resonance imaging : JMRI. 2009. DOI: 10.1002/jmri.21786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.