MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2013.12.011

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2013

Optimization of solvent bar microextraction combined with gas chromatography for preconcentration and determination of methadone in human urine and plasma samples.

Ebrahimzadeh Homeira, Mirbabaei Fatemeh, Asgharinezhad Ali Akbar, Shekari Nafiseh, Mollazadeh Narges

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

In this study, solvent bar microextraction combined with gas chromatography-flame ionization detector (GC-FID) was used for preconcentration and determination of methadone in human body fluids. The target drug was extracted from an aqueous sample with pH 11.5 (source phase) into an organic extracting solvent (1-Undecanol) located inside the pores and lumen of a polypropylene hollow fiber as a receiving phase. To obtain high extraction efficiency, the effect of different variables on the extraction efficiency was studied using an experimental design. The variables of interest were the organic phase type, source phase pH, ionic strength, stirring rate, extraction time, concentration of Triton X-100, and extraction temperature, which were first investigated by Plackett-Burman design and subsequently by central composite design (CCD). So that the optimum experimental condition was obtained when the sodium chloride concentration was 5% (w/v); stirring rate, 700 rpm; extraction temperature, 20 °C; extraction time, 45 min and pH of the aqueous sample, 11.5. Under the optimized conditions, the preconcentration factors were between 275 and 300. The calibration curves were linear in the concentration range of 10-1500 μg L(-1). The limits of detection (LODs) were 2.7-7 and relative standard deviations (RSDs) of the proposed method were 5.9-7.3%. Ultimately, the applicability of the current method was evaluated by the extraction and determination of methadone in different biological samples.

Для цитирования: Ebrahimzadeh Homeira, Mirbabaei Fatemeh, Asgharinezhad Ali Akbar, Shekari Nafiseh, Mollazadeh Narges. Optimization of solvent bar microextraction combined with gas chromatography for preconcentration and determination of methadone in human urine and plasma samples.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2013. DOI: 10.1016/j.jchromb.2013.12.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.