MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1440-1746.2010.06248.x

Медицинская библиотека · Journal of gastroenterology and hepatology · 2010

Carbon dioxide-based portography: an alternative to conventional imaging with the use of iodinated contrast medium.

Maruyama Hitoshi, Okugawa Hidehiro, Ishibashi Hiroyuki, Takahashi Masanori, Kobayashi Satoshi, Yoshizumi Hiroaki, Yokosuka Osamu

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIM: To clarify the efficacy of carbon dioxide (CO(2)) as a contrast material to evaluate portal vein images by percutaneous transhepatic portography (PTP).

METHODS

Twenty patients (38-76 years; male 13, female 7) with chronic liver diseases were the subjects of this prospective study. Portal venous opacification by PTP was compared between CO(2)-based images and iodinated contrast medium (ICM)-based images by two independent reviewers, according to the three-grade scoring; 0 for none, 1 for weak and 2 for sufficient.

RESULTS

Total scores of extrahepatic portal veins (137 for CO(2), 93 for ICM), collateral vessels (64 for CO(2), 60 for ICM) and intrahepatic portal veins (69 for CO(2), 76 for ICM) were not statistically significant between CO(2)-based and ICM-based images (P = 0.0623). Sufficient opacification of superior mesenteric vein was more frequent on CO(2)-based images (none 0, weak 4, sufficient 16) than ICM-based images (none 19, weak 0, sufficient 1; P < 0.0001). The score was not statistically significant between CO(2)-based and ICM-based images in portal trunk, splenic vein, inferior mesenteric vein and other collateral vessels. Although opacification grade in the intrahepatic left portal vein was not statistically significant between CO(2)-based and ICM-based images (P = 0.1515), weak opacification was significantly frequent on CO(2)-based images (weak 10, sufficient 10) compared to ICM-based images (weak 0, sufficient 20; P = 0.0003) in the intrahepatic right portal vein. Inter-reviewer agreement was excellent between the two reviewers for CO(2)-based images (kappa = 0.913) and ICM-based images (kappa = 0.924).

CONCLUSIONS

Carbon dioxide may be a first-line contrast material for evaluating portal vein images by PTP.

Для цитирования: Maruyama Hitoshi, Okugawa Hidehiro, Ishibashi Hiroyuki, Takahashi Masanori, Kobayashi Satoshi, Yoshizumi Hiroaki, Yokosuka Osamu. Carbon dioxide-based portography: an alternative to conventional imaging with the use of iodinated contrast medium.. Journal of gastroenterology and hepatology. 2010. DOI: 10.1111/j.1440-1746.2010.06248.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.