m+Medelevator.RU
← Поиск публикаций
The international journal of cardiovascular imaging · 2019

The effect of contrast agents on left ventricular parameters calculated by a threshold-based software module: does it truly matter?

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Szűcs Andrea, Kiss Anna Réka, Suhai Ferenc Imre, Tóth Attila, Gregor Zsófia, Horváth Márton, Czimbalmos Csilla, Csécs Ibolya, Dohy Zsófia, Szabó Liliána Erzsébet, Merkely Béla, Vágó Hajnalka

Аннотация

The acquisition of short-axis (SA) cine magnetic resonance (MR) images after the administration of contrast agent (CA) is a common, time-saving technique, but a decreased difference in the blood-myocardium contrast on these steady-state free precession (SSFP) cine scans could change the calculated parameters when using threshold-based papillary and trabecular muscle (PTM) quantification. We studied the effect of CA on the parameters calculated from pre- and post-CA SA cine images in noncompaction cardiomyopathy (NC-CMP) and healthy (H) participants using a threshold-based module. A total of 39 individuals (20 patients and 19 healthy) were included prospectively in this study. After the pre-CA SA images were acquired, i.v. gadobutrol (GA) or gadobenate dimeglumine (GD) (GA vs. GD: NC-CMP = 12 vs. 8; C = 12 vs. 7) was administered, and SA scans were repeated after two minutes. A threshold-based PTM software was used for postprocessing. Pre-CA and post-CA SA images were analyzed, and the parameters were compared in both the NC-CMP and H groups. The left ventricular volumes were significantly larger, while the left ventricular myocardial (LVmass) and trabecular mass (LVtrab) values were significantly smaller on the post-CA scans (NC-CMP: pre-CA vs. post-CA, EDV: 74.0 ± 13.6 vs. 81.1 ± 16.3 ml/m2, ESV: 25.3 ± 7.3 vs. 30.1 ± 11.2 ml/m2, LVmass-ED: 82.5 ± 17.5 vs. 75.7 ± 15.9 g/m2, LVtrab-ED: 25.0 ± 6.6 vs. 18.9 ± 4.7 g/m2; Healthy: preCA vs. post-CA, EDV: 69.7 ± 11.9 vs. 72.2  ±  10.7 ml/m2, ESV: 22.6 ± 5.7 vs. 23.9 ± 6.3 ml/m2, LVmass-ED: 71.3 ± 13.6 vs. 68.7 ± 13.9 g/m2, LVtrab-ED: 19.4 ± 2.6 vs. 16.2 ± 3.0 g/m2; p < 0.05). The decreased blood-myocardium contrast difference on post-CA SSFP SA cine images leads to altered cardiac parameters when using threshold-based software for evaluation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты