m+Medelevator.RU
← Поиск публикаций
Circulation. Cardiovascular quality and outcomes · 2019

Low-Value Transthoracic Echocardiography, Healthcare Utilization, and Clinical Outcomes in Patients With Coronary Artery Disease.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tharmaratnam Tharmegan, Bouck Zachary, Sivaswamy Atul, Wijeysundera Harindra C, Chu Cherry, Yin Cindy X, Nesbitt Gillian C, Edwards Jeremy, Yared Kibar, Wong Brian, Weinerman Adina, Thavendiranathan Paaladinesh, Rakowski Harry, Dorian Paul, Anderson Geoff, Austin Peter C, Dudzinski David M, Ko Dennis T, Weiner Rory B, Bhatia R Sacha

Аннотация

BACKGROUND: The relationship between ordering frequency of rarely appropriate transthoracic echocardiograms on healthcare utilization and patient outcomes in coronary artery disease (CAD) is not known. Our objective was to investigate practice patterns of cardiologists who order a high frequency of low-value transthoracic echocardiograms in patients with CAD and whether practice behavior influences patient outcomes.

METHODS AND RESULTS: A retrospective cohort of outpatient CAD patients was accrued by identifying patients with at least 1 visit to 1 of 35 Ontario-based cardiologists in the EchoWISELY randomized clinical trial (Will Inappropriate Scenarios for Echocardiography Lessen Significantly) control group. The main outcomes of interest were patient-level receipt of diagnostic tests, physician visits, medication prescriptions, and clinical outcomes at 1 year. Our cohort consisted of 3966 patients with CAD (mean [SD] age, 67.8 [12.0] years; 72% men), with an outpatient visit to 1 of 35 eligible cardiologists, stratified into 3 ordering tertiles. Patients of cardiologists in the top ordering tertile of rarely appropriate transthoracic echocardiograms had significantly lower odds of receiving the following services at 1 year compared with patients in the low ordering group: cholesterol assessment (odds ratio [OR], 0.77 [95% CI, 0.65-0.91]); hemoglobin A1c assessment (OR, 0.79 [95% CI, 0.66-0.94]); β-blocker prescription (OR, 0.70 [95% CI, 0.55-0.90]); and aldosterone receptor antagonist prescription (OR, 0.46 [95% CI, 0.22-0.98]). Patients of high ordering cardiologists had greater odds of all-cause mortality at 1 year (OR, 1.54 [95% CI, 1.04-2.28]), although all other outcomes were similar.

CONCLUSIONS: Patients with CAD seen by cardiologist who ordered a high rate of rarely appropriate transthoracic echocardiograms were less likely to receive potentially high-value screening tests and evidence-based medications than low ordering cardiologists.

CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02038101.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты