MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.aca.2007.09.007

Медицинская библиотека · Analytica chimica acta · 2007

A novel potentiometric biosensor for selective L-cysteine determination using L-cysteine-desulfhydrase producing Trichosporon jirovecii yeast cells coupled with sulfide electrode.

Hassan Saad S M, el-Baz Ashraf F, Abd-Rabboh Hisham S M

СтатьяПеревод в очереди

Аннотация

Trichosporon jirovecii yeast cells are used for the first time as a source of L-cysteine desulfhydrase enzyme (EC 4.4.1.1) and incorporated in a biosensor for determining L-cysteine. The cells are grown under cadmium stress conditions to increase the expression level of the enzyme. The intact cells are immobilized on the membrane of a solid-state Ag2S electrode to provide a simple L-cysteine responsive biosensor. Upon immersion of the sensor in L-cysteine containing solutions, L-cysteine undergoes enzymatic hydrolysis into pyruvate, ammonia and sulfide ion. The rate of sulfide ion formation is potentiometrically measured as a function of L-cysteine concentration. Under optimized conditions (phosphate buffer pH 7, temperature 37+/-1 degrees C and actual weight of immobilized yeast cells 100 mg), a linear relationship between L-cysteine concentration and the initial rate of sulfide liberation (dE/dt) is obtained. The sensor response covers the concentration range of 0.2-150 mg L(-1) (1.7-1250 micromol L(-1)) L-cysteine. Validation of the assay method according to the quality control/quality assurance standards (precision, accuracy, between-day variability, within-day reproducibility, range of measurements and lower limit of detection) reveals remarkable performance characteristics of the proposed biosensor. The sensor is satisfactorily utilized for determination of L-cysteine in some pharmaceutical formulations. The lower limit of detection is approximately 1 micromol L(-1) and the accuracy and precision of the method are 97.5% and +/-1.1%, respectively. Structurally similar sulfur containing compounds such as glutathione, cystine, methionine, and D-cysteine do no interfere.

Для цитирования: Hassan Saad S M, el-Baz Ashraf F, Abd-Rabboh Hisham S M. A novel potentiometric biosensor for selective L-cysteine determination using L-cysteine-desulfhydrase producing Trichosporon jirovecii yeast cells coupled with sulfide electrode.. Analytica chimica acta. 2007. DOI: 10.1016/j.aca.2007.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.