Fertility and sterility · 1999
Cytogenetic diagnosis of "normal 46,XX" karyotypes in spontaneous abortions frequently may be misleading.
СтатьяПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bell K A, Van Deerlin P G, Haddad B R, Feinberg R F
Аннотация
OBJECTIVE: To use the molecular identification of Y chromosome material in products of conception cytogenetically diagnosed as "46,XX" to confirm the occurrence of inaccurate cytogenetic test results most likely attributable to maternal cell contamination.
DESIGN: Retrospective analysis.
SETTING: Academic medical center.
PATIENT(S): Thirty-four archival tissues from cases of spontaneous abortion with a "46,XX" karyotype based on cytogenetic analysis.
INTERVENTION(S): Maternal and villus DNA were extracted from microdissected, formalin-fixed, paraffin-embedded archival tissues. The presence of the X and Y chromosomes was detected with the use of polymerase chain reaction assays and confirmed with fluorescence in situ hybridization.
MAIN OUTCOME MEASURE(S): Accuracy of cytogenetic evaluation of products of conception.
RESULT(S): Four (29%) of 14 first trimester and 1 (5%) of 20 second trimester "46,XX" pregnancy losses contained Y chromosome-specific DNA and demonstrated a single X chromosome-specific allele by polymerase chain reaction analysis consistent with an "XY" karyotype. Fluorescence in situ hybridization was confirmatory in 4 of 5 samples that demonstrated single X and Y signals in villus cells.
CONCLUSION(S): Inaccuracy exists in the cytogenetic analysis of early products of conception that most likely is due to maternal cell contamination. In the absence of confirmatory testing, such as with a "DNA fingerprinting" assay, reports of a "46,XX" karyotype should be used cautiously in patient counseling and management.
DESIGN: Retrospective analysis.
SETTING: Academic medical center.
PATIENT(S): Thirty-four archival tissues from cases of spontaneous abortion with a "46,XX" karyotype based on cytogenetic analysis.
INTERVENTION(S): Maternal and villus DNA were extracted from microdissected, formalin-fixed, paraffin-embedded archival tissues. The presence of the X and Y chromosomes was detected with the use of polymerase chain reaction assays and confirmed with fluorescence in situ hybridization.
MAIN OUTCOME MEASURE(S): Accuracy of cytogenetic evaluation of products of conception.
RESULT(S): Four (29%) of 14 first trimester and 1 (5%) of 20 second trimester "46,XX" pregnancy losses contained Y chromosome-specific DNA and demonstrated a single X chromosome-specific allele by polymerase chain reaction analysis consistent with an "XY" karyotype. Fluorescence in situ hybridization was confirmatory in 4 of 5 samples that demonstrated single X and Y signals in villus cells.
CONCLUSION(S): Inaccuracy exists in the cytogenetic analysis of early products of conception that most likely is due to maternal cell contamination. In the absence of confirmatory testing, such as with a "DNA fingerprinting" assay, reports of a "46,XX" karyotype should be used cautiously in patient counseling and management.