MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijpvm.ijpvm_337_17

Медицинская библиотека · International journal of preventive medicine · 2019

Using the Blood Coagulation Factors as a Predictor Component of the Occupational Vibration Exposure.

Yadegari Mehrdad, Pourabdian Siamak, Forouharmajd Farhad

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Exposure to hand-arm vibrations higher than permissible standard rates can have destructing effects on workers' health. Pneumatic hammers are among the tools that are used in civil and industrial projects, transferring high vibration acceleration to the workers. This study has considered the probable effects of hand-arm vibrations on the performance of blood coagulation factors in the workers using this tool and exposed to high vibration acceleration.

METHODS

Five new workers without any experience in exposure with hand-arm vibrations were selected for this interventional study. Blood sample was taken from each worker before they started working for the required analysis. Sampling was repeated in two other stages in 2-month intervals from the first sampling, whereas the workers were then experienced in working with pneumatic hammers. Measuring the vibration of the pneumatic hammer was done according to ISO 28927-10 standard.

RESULTS

The point of measuring the vibration acceleration was selected close to the hand, in accordance with the standard. Regarding the exposure time of the workers, the amount of vibration acceleration was obtained 15.54 m/s2. Activated partial thromboplastin times of four samples in the second and third stages have shown increases in comparison to the first stage in that respect. On the other hand, a number of red blood cells, white blood cells, and platelets did not show a consistent trend in the three stages.

CONCLUSIONS

The considered samples showed longer time for blood coagulation as compared to the reference time. Thus, it can be concluded that the main reason is the acceleration in three different coordinate axes of x, y, and z. Hence, the values beyond permissible standard rate of hand-arm vibration in 8 h shifts affect the blood parameters, among which the considered coagulation parameters in this study showed more tangible changes in that respect.

Для цитирования: Yadegari Mehrdad, Pourabdian Siamak, Forouharmajd Farhad. Using the Blood Coagulation Factors as a Predictor Component of the Occupational Vibration Exposure.. International journal of preventive medicine. 2019. DOI: 10.4103/ijpvm.ijpvm_337_17.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.