m+Medelevator.RU
← Поиск публикаций
Analytical chemistry · 2007

CdS nanocrystal-based electrochemiluminescence biosensor for the detection of low-density lipoprotein by increasing sensitivity with gold nanoparticle amplification.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jie Guifen, Liu Bo, Pan Hongcheng, Zhu Jun-Jie, Chen Hong-Yuan

Аннотация

Mercaptoacetic acid (RSH)-capped CdS nanocrystals (NCs) was demonstrated to be electrochemically reduced during potential scan and react with the coreactant S2O8(2-) to generate strong electrochemiluminescence (ECL) in aqueous solution. Based on the ECL of CdS NCs, a novel label-free ECL biosensor for the detection of low-density lipoprotein (LDL) has been developed by using self-assembly and gold nanoparticle amplification techniques. The biosensor was prepared as follows: The gold nanoparticles were first assembled onto a cysteamine monolayer on the gold electrode surface. This gold nanoparticle-covered electrode was next treated with cysteine and then reacted with CdS NCs to afford a CdS NC-electrode. Finally, apoB-100 (ligand of LDL receptor) was covalently conjugated to the CdS NC-electrode. The modification procedure was characterized by cyclic voltammetry, electrochemical impedance spectroscopy, and atomic force microscopy, respectively. The resulting modified electrode was tested as ECL biosensor for LDL detection. The LDL concentration was measured through the decrease in ECL intensity resulting from the specific binding of LDL to apoB-100. The ECL peak intensity of the biosensor decreased linearly with LDL concentration in the range of 0.025-16 ng mL-1 with a detection limit of 0.006 ng mL-1. The CdS NCs not only showed high ECL intensity and good biocompatibility but also could provide more binding sites for apoB-100 loading. In addition, the gold nanoparticle amplification for protein ECL analysis was applied to the improvement of the detection sensitivity. Thus, the biosensor exhibited high sensitivity, good reproducibility, rapid response, and long-term stability.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты