Accuracy comparison of MR elastography and biological markers in detecting liver fibrosis and predicting postoperative ascites.
Аннотация
BACKGROUND
This retrospective study aimed to compare the discriminative performance between magnetic resonance elastography (MRE) and biological markers in detecting liver fibrosis and in predicting postoperative ascites (PA).
METHODS
We enrolled 77 patients consecutively who underwent hepatectomy between March 2017 and June 2019. Liver fibrosis was histopathologically graded using the METAVIR scoring system as reference. Discriminative performance of non-invasive assessments in detecting different stages of liver fibrosis and predicting PA was evaluated by receiver-operator curve analysis.
RESULTS
The concordance indices (C-indices) for MRE and biological markers for detecting significant fibrosis (≥F2) and cirrhosis (F4) were: MRE, 0.84 and 0.86; Wisteria floribunda agglutinin + Mac-2 binding protein (WM2BP), 0.63 and 0.71; Hyaluronic acid (HA), 0.72 and 0.75; 7 S-type 4 collagen (T4C), 0.61 and 0.66; APRI, 0.76 and 0.83; and Fib-4, 0.75 and 0.76. Univariable logistic analysis for predicting PA showed that C-indices were 0.751 (p = 0.007), 0.798 (p = 0.106), 0.771 (p = 0.050), 0.674 (p = 0.855), 0.655 (p = 0.263), and 0.560 (p = 0.640) for MRE, WM2BP, Fib-4, HA, APRI, and T4C, respectively.
CONCLUSION
MRE has a higher diagnostic performance than biological markers in detecting the stages of liver fibrosis and is a predictor for PA after hepatectomy.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.