Supraglottic airway device versus tracheal intubation and the risk of emergent postoperative intubation after general anaesthesia in adults: a retrospective cohort study.
Аннотация
BACKGROUND
We examined the association between emergent postoperative tracheal intubation and the use of supraglottic airway devices (SGAs) vs tracheal tubes.
METHODS
We included data from adult noncardiac surgical cases under general anaesthesia between 2008 and 2018. We only included cases (n=59 991) in which both airways were deemed to be feasible options. Multivariable logistic regression, instrumental variable analysis, propensity matching, and mediation analysis were used.
RESULTS
Use of a tracheal tube was associated with a higher risk of emergent postoperative intubation (adjusted absolute risk difference [ARD]=0.80%; 95% confidence interval (CI), 0.64-0.97; P<0.001), and a higher risk of post-extubation hypoxaemia (ARD=3.9%; 95% CI, 3.4-4.4; P<0.001). The effect was modified by the use of non-depolarising neuromuscular blocking agents (NMBAs); mediation analyses revealed that 28.9% (95% CI, 14.4-43.4%; P<0.001) of the main effect was attributable to NMBA. Airway management modified the association of NMBA and risk of emergent postoperative intubation (Pinteraction=0.02). Patients managed with an SGA had higher odds of NMBA-associated reintubation compared to patients managed with a tracheal tube (adjusted odds ratio [aOR]=3.65, 95% CI, 1.99-6.67 vs aOR=1.68, 95% CI, 1.29-2.18 [P<0.001], respectively).
CONCLUSIONS
In patients undergoing procedures under general anaesthesia that could be managed with either SGA or tracheal tube, use of an SGA was associated with lower risk of emergent postoperative intubation. The effect can partly be explained by use of NMBAs. Use of NMBAs in patients with an SGA appears to increase the risk of emergent postoperative intubation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.