MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s0392-9590.24.05287-8

Медицинская библиотека · International angiology : a journal of the International Union of Angiology · 2024

Saphenous vein versus synthetic graft in arteriovenous fistula for hemodialysis in patient with inaccessible veins.

Galal Ali M, Ismail Mohamed A, Abdrabo Marco S, Mahmoud Ahmed K

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

An autologous arteriovenous fistula (AVF) provides an optimal and secure way for managing the condition. An optimal blood supply to hemodialysis is linked to decreased incidence of complications and mortality, as well as reduced expenses. The objective of this research was to evaluate the outcome of people with suboptimal superficial venous system quality or who had exhausted all available arteriovenous fistula options, who received either autologous saphenous vein graft or polytetrafluoroethylene (PTFE) interposition graft as an access for effective hemodialysis.

METHODS

This prospective randomized controlled trail was carried out on fifty cases with chronic renal failure on hemodialysis and inaccessible superficial veins of both upper limbs for AVF. Cases were separated into two equal groups: Group A: cases performed saphenous vein reposition graft for hemodialysis access. Group B: cases who underwent PTFE interposition graft for prosthetic hemodialysis access.

RESULTS

Time for maturation and time for graft maturation, operative time, hospital stay, and postoperative HB were significant increase in group A in contrast to group B (P<0.05). Blood loss was significant decrease in group A in contrast to group B (P<0.001).

CONCLUSIONS

Patients underwent saphenous vein repositioning graft for hemodialysis access required prolonged operative time and hospital stay. Cases that underwent PTFE interposition graft for prosthetic hemodialysis access were less in time for maturation and time for graft maturation.

Для цитирования: Galal Ali M, Ismail Mohamed A, Abdrabo Marco S, Mahmoud Ahmed K. Saphenous vein versus synthetic graft in arteriovenous fistula for hemodialysis in patient with inaccessible veins.. International angiology : a journal of the International Union of Angiology. 2024. DOI: 10.23736/s0392-9590.24.05287-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.