m+Medelevator.RU
← Поиск публикаций
Anaesthesia · 2024

Efficacy of high-flow nasal oxygenation during induction of general anaesthesia in parturients living with obesity: a two-centre, prospective, randomised clinical trial.

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhou Shuang-Qiong, Lian Jian-Feng, Zhou Yao, Cao Xiu-Hong, Ni Xiu, Zhang Xiao-Peng, Xu Zhen-Dong, Xiao Quan-Sheng, Liu Zhi-Qiang

Аннотация

INTRODUCTION: High-flow nasal oxygenation has been shown to improve oxygenation during induction of anaesthesia in parturients who are not obese. However, data on the efficacy of high-flow nasal oxygen in parturients living with obesity are lacking. This study investigated the effects of high-flow nasal oxygenation on pre-oxygenation and apnoea oxygenation during tracheal intubation in parturients living with obesity.

METHODS: This prospective, randomised clinical trial was conducted at two tertiary hospitals and included parturients with BMI > 30 kg.m-2 undergoing scheduled caesarean delivery under general anaesthesia. Parturients were allocated randomly to standard facemask or high-flow nasal oxygen groups (oxygen flow rates 10 l.min-1 and 50 l.min-1, respectively). The primary outcome measure was arterial partial pressure of oxygen after 3 min of pre-oxygenation.

RESULTS: 54 patients completed the study. The arterial partial pressure of oxygen after 3 min of pre-oxygenation was significantly lower in parturients allocated to the standard facemask group compared with those allocated to the high-flow nasal oxygen group (mean (SD) 40.1 (8.9) kPa vs. 53.8 (9.7) kPa, p < 0.001). End-tidal oxygen concentration on commencing ventilation was also lower in parturients allocated to the standard facemask group compared with those allocated to the high flow-nasal oxygen group (mean (SD) 78.3 (5.38)% vs. 86.2 (5.10)%, p < 0.001). The arterial partial pressure of carbon dioxide post tracheal intubation and fetal outcomes were similar in both groups.

DISCUSSION: Pre-oxygenation using high-flow nasal oxygenation provided a higher arterial partial pressure of oxygen and end-tidal oxygen concentration during general anaesthesia induction than standard facemask oxygenation in parturients living with obesity; however, the differences were not clinically meaningful. High-flow nasal oxygenation may be considered as an alternative option for pre-oxygenation during rapid sequence induction in parturients living with obesity.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты