m+Medelevator.RU
← Поиск публикаций
ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2021

Extracorporeal Life Support for Cardiogenic Shock With Either a Percutaneous Ventricular Assist Device or an Intra-Aortic Balloon Pump.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nakajima Tomohiro, Tanaka Yuki, Fischer Irene, Kotkar Kunal, Damiano Ralph J, Moon Marc R, Masood Muhammad F, Itoh Akinobu

Аннотация

Extracorporeal life support (ECLS) can result in complications due to increased left ventricular (LV) afterload. The percutaneous ventricular assist device (PVAD) and intra-aortic balloon pump (IABP) are both considered to be effective means of LV unloading. This study describes the efficacy of LV unloading and related outcomes with PVAD or IABP during ECLS. From January 2010 to April 2018, all cardiogenic shock patients who underwent ECLS plus simultaneous PVAD or IABP were analyzed. Forty-nine patients received ECLS + PVAD, while 91 received ECLS + IABP. At 48 hours, mean pulmonary artery pressure was significantly reduced in both groups [34 mm Hg to 22, p < 0.01; 32 mm Hg to 21, p < 0.01; ECLS + PVAD and ECLS + IABP group, respectively]. The two groups had similar 30 day survival rates [19 patients (39%) vs. 35 (39%), p = 0.56]. The ECLS + PVAD group had higher incidences of bleeding at the insertion site [11 (22%) vs. 0, p < 0.01] and major hemolysis [9 (18%) vs. 0, p < 0.01]. Both groups had improvement in LV end-diastolic dimension (61 ± 12 mm to 54 ± 12, p = 0.03; 60 ± 12 mm to 47 ± 10, p < 0.01), and LV ejection fraction (16 ± 7% to 22 ± 10, p < 0.01; 22 ± 12% to 29 ± 15, p = 0.01). Both ECLS + PVAD and ECLS + IABP effectively reduced pulmonary artery pressure and improved LV function. Bleeding at the PVAD or IABP insertion site occurred more frequently in the ECLS + PVAD group than the ECLS + IABP group (p < 0.01). Nine patients (18%) in the ECLS + PVAD group experienced major hemolysis, while there was no hemolysis in the ECLS + IABP group (p < 0.01). Careful considerations are required before selecting an additional support to ECLS.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты