MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.20357

Медицинская библиотека · Magnetic resonance in medicine · 2005

Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy.

Mirsattari Seyed M, Ives John R, Bihari Frank, Leung L Stan, Menon Ravi S, Bartha Robert

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод в очереди

Аннотация

Simultaneous recording of electroencephalogram (EEG) and functional MRI (fMRI) or MR spectroscopy (MRS) can provide further insight into our understanding of the underlying mechanisms of neurologic disorders. Current technology for simultaneous EEG and MRI recording is limited by extensive postacquisition processing of the data. Real-time display of artifact-free EEG recording during fMRI/MRS studies is essential in studies that involve epilepsy to ensure that they address specific EEG features such as epileptic spikes or seizures. By optimizing the EEG recording equipment to maximize the common mode rejection ratio of its amplifiers, a unique EEG system was designed and tested that allowed real-time display of the artifact-free EEG during fMRI/MRS in an animal model of epilepsy. Spike recordings were optimized by suppression of the background EEG activity using fast-acting and easily controlled inhalational anesthesia. Artifact suppression efficiency of 70-100% was achieved following direct subtraction of referentially recorded filtered EEG tracings from active electrodes, which were located in close proximity to each other (over homologous occipital cortices) and a reference electrode. Two independent postacquisition processing tools, independent component analysis and direct subtraction of unfiltered digital EEG data in MATLAB, were used to verify the accuracy of real-time EEG display.

Для цитирования: Mirsattari Seyed M, Ives John R, Bihari Frank, Leung L Stan, Menon Ravi S, Bartha Robert. Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy.. Magnetic resonance in medicine. 2005. DOI: 10.1002/mrm.20357.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.