Archives of pediatrics & adolescent medicine · 1995
Precision and accuracy of clinical and radiological signs in premature infants at risk of patent ductus arteriosus.
Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Davis P, Turner-Gomes S, Cunningham K, Way C, Roberts R, Schmidt B
Аннотация
OBJECTIVE: To determine the precision (interobserver agreement) and accuracy (agreement with criterion standard) of clinical and radiological signs in premature infants at risk of patent ductus arteriosus (PDA) with left-to-right shunting.
DESIGN: Masked comparison of clinical and radiological examination with Doppler flow echocardiography (criterion standard).
SETTING: Neonatal intensive care unit.
PATIENTS: One hundred infants with birth weights less than 1750 g were studied once between days 3 and 7 of life. A third of the cohort was intubated at the time of study.
INTERVENTION: Five independent observers noted the presence or absence of an increased pulse volume, an active precordium, a heart murmur, a cardiothoracic ratio greater than 60%, increased pulmonary vascular markings on a concurrent chest x-ray film, and a relative increase of the cardiothoracic ratio compared with that from the previous chest x-ray film. Pulsed and color flow Doppler echocardiography was performed within 4 hours. All 100 tapes were reviewed by a second pediatric cardiologist.
RESULTS: Twenty-three infants had a PDA with left-to-right shunting. The precision of clinical signs was modest, with average kappa values of 0.15 for pulse volume, 0.32 for precordium, and 0.41 for murmur. Pulse quality (43%) and murmur (42%) had the highest mean sensitivities. Corresponding specificities were 74% for pulse volume and 87% for murmur. The combination of a cardiac murmur with an abnormal pulse volume had the highest positive predictive value (77%). The radiological examination did not improve the observers' ability to distinguish between patients with and without PDA.
CONCLUSIONS: The precision and accuracy of clinical and radiological signs of a PDA with left-to-right shunting are unsatisfactory. Therefore, Doppler flow echocardiography is required to diagnose PDA confidently in preterm infants between days 3 and 7 of life.
DESIGN: Masked comparison of clinical and radiological examination with Doppler flow echocardiography (criterion standard).
SETTING: Neonatal intensive care unit.
PATIENTS: One hundred infants with birth weights less than 1750 g were studied once between days 3 and 7 of life. A third of the cohort was intubated at the time of study.
INTERVENTION: Five independent observers noted the presence or absence of an increased pulse volume, an active precordium, a heart murmur, a cardiothoracic ratio greater than 60%, increased pulmonary vascular markings on a concurrent chest x-ray film, and a relative increase of the cardiothoracic ratio compared with that from the previous chest x-ray film. Pulsed and color flow Doppler echocardiography was performed within 4 hours. All 100 tapes were reviewed by a second pediatric cardiologist.
RESULTS: Twenty-three infants had a PDA with left-to-right shunting. The precision of clinical signs was modest, with average kappa values of 0.15 for pulse volume, 0.32 for precordium, and 0.41 for murmur. Pulse quality (43%) and murmur (42%) had the highest mean sensitivities. Corresponding specificities were 74% for pulse volume and 87% for murmur. The combination of a cardiac murmur with an abnormal pulse volume had the highest positive predictive value (77%). The radiological examination did not improve the observers' ability to distinguish between patients with and without PDA.
CONCLUSIONS: The precision and accuracy of clinical and radiological signs of a PDA with left-to-right shunting are unsatisfactory. Therefore, Doppler flow echocardiography is required to diagnose PDA confidently in preterm infants between days 3 and 7 of life.