Sensitivity of contrast ultrasound in the detection of atrial septal defect with predominant left-to-right shunting.

Hajduczok Z D, Winniford M D, Kerber R E

СтатьяПеревод в очереди

Аннотация

Ultrasound contrast techniques are used widely as a screening test for intracardiac shunt. We performed a retrospective analysis of contrast echocardiograms in 29 consecutive patients with atrial septal defect (excluding Eisenmenger's) proved by cardiac catheterization. A positive (right-to-left atrial) ultrasound contrast effect was seen in 25 patients in whom catheterization pulmonary-to-systemic flow rate (Qp/Qs) was 2.2 +/- 0.9 (SD). Four patients had false-negative contrast echocardiography results; their Qp/Qs was 2.9 +/- 0.4 (p = 0.07). The percent left-to-right shunt was higher in the group with false-negative contrast echocardiographic results (65% +/- 4% vs 47% +/- 21%) (p = 0.05). Shunts with Qp/Qs < or = 2.0 had a sensitivity of 100%, whereas those with Qp/Qs > or = 2.1 had a sensitivity of 73%. In the four false-negative contrast echocardiographic results, three had findings of an atrial septal defect by pulsed Doppler, color Doppler, or both. Thus the presence of a large left-to-right shunt may decrease the sensitivity of the ultrasound contrast technique for the detection of an atrial septal defect. Contrast ultrasonography should be used in conjunction with Doppler and two-dimensional echocardiography criteria for diagnosis of atrial septal defect.

Для цитирования: Hajduczok Z D, Winniford M D, Kerber R E. Sensitivity of contrast ultrasound in the detection of atrial septal defect with predominant left-to-right shunting.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 1992. DOI: 10.1016/s0894-7317(14)80038-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.