Clinical, cosmetic and investigational dermatology · 2022
A Probing of the Issue of Detecting IgG, IgG4 and IgA Antibodies to Laminin 332 Epitopes in Mucous Membrane Pemphigoid: A Clinical-Laboratory Experience of a Single Central European University Dermatology Department.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Gornowicz-Porowska Justyna, Jałowska Magdalena, Seraszek-Jaros Agnieszka, Bowszyc-Dmochowska Monika, Kaczmarek Elżbieta, Dmochowski Marian
Аннотация
PURPOSE: Mucous membrane pemphigoid (MMP) is a very rare autoimmune bullous disease, affecting predominantly the mucosae and characterized by autoantibodies to the epithelial basement membrane components. Laminin 332 (Ln-332) is one of the most probable antigens with association with malignancy. The laboratory diagnosis of Ln-332-mediated autoimmunity is troublesome. The aim here was to comparatively examine IgG, IgG4, and IgA autoantibodies specific to α3, β3 or γ2 subunits of Ln-322 in MMP patients using the BIOCHIP mosaic-based indirect immunofluorescence technique (IIF).
PATIENTS AND METHODS: Sera from 15 MMP patients were studied. BIOCHIP mosaic-based Ln-332 IIF, direct immunofluorescence, ELISA tests for anti-BP180/BP20 IgG antibodies and statistical analyses were performed.
RESULTS: Of all the 15 sera examined for IgG4 antibodies, only 1 (6.67%) reacted with the α3 chain, 0 with the β3 chain, and 0 with the γ2 chain. No positive reactivity was seen with the IgG and IgA antibodies. BIOCHIP mosaic-based IIF with Ln-332 showed 100% sensitivity, 8% specificity, 21% positive predictive value, and 100% negative predictive value in relation to the diagnostic gold standard of DIF. The concomitant malignancies were revealed in three cases.
CONCLUSION: The detection of antibodies to Ln-332 chains is occasional in Polish MMP sufferers. Still, the evaluation of IgG4 antibodies in MMP can reduce the false-negative results.
PATIENTS AND METHODS: Sera from 15 MMP patients were studied. BIOCHIP mosaic-based Ln-332 IIF, direct immunofluorescence, ELISA tests for anti-BP180/BP20 IgG antibodies and statistical analyses were performed.
RESULTS: Of all the 15 sera examined for IgG4 antibodies, only 1 (6.67%) reacted with the α3 chain, 0 with the β3 chain, and 0 with the γ2 chain. No positive reactivity was seen with the IgG and IgA antibodies. BIOCHIP mosaic-based IIF with Ln-332 showed 100% sensitivity, 8% specificity, 21% positive predictive value, and 100% negative predictive value in relation to the diagnostic gold standard of DIF. The concomitant malignancies were revealed in three cases.
CONCLUSION: The detection of antibodies to Ln-332 chains is occasional in Polish MMP sufferers. Still, the evaluation of IgG4 antibodies in MMP can reduce the false-negative results.