m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2012

Comparison of efficacy and safety of intracoronary sodium nitroprusside and intravenous adenosine for assessing fractional flow reserve.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rudzinski Wojciech, Waller Alfonso H, Rusovici Arthur, Dehnee Abed, Nasur Ali, Benz Michael, Sanchez Salvador, Klapholz Marc, Kaluski Edo

Аннотация

OBJECTIVES: The purpose of this study was to compare the efficacy and safety of intracoronary (IC) nitroprusside and intravenous adenosine (IVA) for assessing fractional flow reserve (FFR).

BACKGROUND: IV infusion of adenosine is a standard method to achieve a coronary hyperemia for FFR measurement. However, adenosine is expensive, causes multiple side effects, and is contraindicated in patients with reactive airway disease. Sodium nitroprusside (NTP) is a strong coronary vasodilator but its efficacy and safety for assessing FFR is not well established.

METHODS: We compared FFR response and side effects profile of IC NTP and IVA. Bolus of NTP at a dose of 100 μg and IVA (140 μg/kg/min) were used to achieve coronary hyperemia.

RESULTS: We evaluated 75 lesions in 53 patients (60% male) mean age 61.6 ± 13.9 years. Mean FFR after NTP was similar to FFR after adenosine (0.836 ± 0.107 vs. 0.856 ± 0.106; P = 0.26; r = 0.91, P < 0.001). NTP induced maximal stable hyperemia within 10 sec (mean: 6.4 ± 1) which lasted consistently between 38 and 60 sec (mean 51 ± 7.5). NTP caused significant (14%), but asymptomatic decrease in mean blood pressure which returned to baseline within 60 sec. Adenosine caused shortness of breath in 26%, headache and flushing in 19%, and transient second degree heart block in 6% of patients. No adverse symptoms were reported after NTP.

CONCLUSIONS: IC NTP is as effective as IVA for measuring FFR. NTP is better tolerated by patients. Since NTP is inexpensive, readily available, well tolerated, and safe, it may be a better choice for FFR assessment.