Медицинская библиотека · Journal of women's health (2002) · 2015

Impact of utilizing a women-based formula for determining adequacy of the chronotropic response during exercise treadmill testing.

Abdelmoneim Sahar S, Gulati Martha, Mulvagh Sharon L, Pack Quinn, Scott Christopher G, Barr Laurie, Allison Thomas G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A women-based formula for calculation of age-predicted maximum heart rate [age-predicted maximum heart rate=206-(0.88×age)] was established in asymptomatic volunteer women undergoing treadmill exercise tolerance testing (ETT). We sought to perform a comparison of the performance of this women-based formula for prediction of peak heart rate to the traditional formula [220-age] and our own database-generated prediction formula in a large database of women undergoing ETT.

METHODS

We performed a retrospective analysis of all consecutive women who underwent symptom-limited Bruce protocol ETT at the Mayo Clinic from 1994 to 2010. Women with known cardiovascular disease or those using beta blockers, calcium channel blockers, or digitalis were excluded. Separate analyses were performed according to symptomatic status.

RESULTS

The study included 11,029 women (89.4% Caucasian) with a mean age 52±12 years; 3,632 (33%) were referred specifically for evaluation of symptoms. Age-predicted maximum heart rate calculated by the traditional formula was achieved by 49.7% of women versus 69.9% by the women-based formula with most of the underestimation observed in older women. Average absolute deviation between achieved and predicted peak heart rate (HR) was 10.85±9.18 bpm for traditional versus 11.98±9.00 for women-based formulas (dependent t=-16.64, p<0.0001). The linear regression line calculated from our population [HR=201-(0.67×age)] was closer to the women-based formula, both in terms of intercept and slope than the traditional formula. Peak HR was shown to be slightly affected (-2.5 bpm) by symptom status at referral, whereas smoking and diabetes more significantly reduced achieved peak HR.

CONCLUSIONS

The women-based formula underestimated peak HR, especially in older women, but was observed to be closer in both intercept and slope to the regression line determined from our study in this large population of female patients. These sex-unique observations should be taken into account when determining adequacy and targets for ETT in women.

Для цитирования: Abdelmoneim Sahar S, Gulati Martha, Mulvagh Sharon L, Pack Quinn, Scott Christopher G, Barr Laurie, Allison Thomas G. Impact of utilizing a women-based formula for determining adequacy of the chronotropic response during exercise treadmill testing.. Journal of women's health (2002). 2015. DOI: 10.1089/jwh.2014.4935.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.