MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/es0114557

Медицинская библиотека · Environmental science & technology · 2002

Development, operation, and long-term performance of a full-scale biocurtain utilizing bioaugmentation.

Dybas Michael J, Hyndman David W, Heine Robert, Tiedje James, Linning Katrina, Wiggert David, Voice Thomas, Zhao Xianda, Dybas Leslie, Criddle Craig S

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

A full-scale field evaluation of bioaugmentation was conducted in a carbon tetrachloride (CT)- and nitrate-impacted aquifer at Schoolcraft, MI. The added organism was Pseudomonas stutzeri KC (strain KC), a denitrifying bacterium that cometabolically degrades CT without producing chloroform (CF). To introduce and maintain strain KC in the aquifer, a row of closely spaced (1-m) injection/extraction wells were installed normal to the direction of groundwater flow near the leading edge of the CT plume. The resulting system of wells was used to establish and maintain a "biocurtain" for CT degradation through the intermittent addition of base to create favorable pH conditions; inoculation; and weekly addition of acetate (electron donor), alkali, and phosphorus. Although half of the test zone was inoculated twice, the long-term performance of both sections was indistinguishable: both had high CT removal efficiencies (median of 98-99.9%) and similar levels of strain KC colonization (>10(5) strain KC/g). Sustained and efficient (98%) removal of CT has now been observed over 4 yr. Transient low levels of CF (<20 ppb) and H2S (<2 ppm) were observed, but both disappeared when the concentration of acetate in the weekly feed was reduced. Nitrate removal efficiencies ranged from 60% at low acetate concentrations to nearly 100% at high acetate concentrations. We conclude that closely spaced wells and intermittent substrate addition are effective means of delivering organisms and substrates to subsurface environments. At the Schoolcraft site, we achieved uniform removal efficiencies over a significant vertical depth (15 m), despite significant variability in hydraulic conductivity. This was accomplished by pumping 65% (v/v) of the natural gradient flow passing through the biocurtain during a given week in a single 6-h pumping event. Approximately 18,600 m3 of contaminated groundwater was treated during the project.

Для цитирования: Dybas Michael J, Hyndman David W, Heine Robert, Tiedje James, Linning Katrina, Wiggert David, Voice Thomas, Zhao Xianda, Dybas Leslie, Criddle Craig S. Development, operation, and long-term performance of a full-scale biocurtain utilizing bioaugmentation.. Environmental science & technology. 2002. DOI: 10.1021/es0114557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.