Noise insertion in CT for cocaine body packing: where is the limit of extensive dose reduction?

Aissa Joel, Bölke Edwin, Sawicki Lino M, Appel Elisabeth, Thomas Christoph, Heusch Philipp, Sedlmair Martin, Krzymyk Karl, Kröpil Patric, Antoch Gerald, Boos Johannes

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate the detection rate and image quality in CT-body-packer-screening at different radiation-dose levels and to determine a dose threshold that enables a reliable detection of incorporated body packs and incidental findings with a maximum of dose saving.

MATERIALS AND

METHODS

We retrospectively included 27 individuals who underwent an abdominal CT with automated exposure control due to suspected body packing. CT images were reconstructed at different radiation-dose levels of 50%, 10, 5% and 1% using iterative reconstructions. All 135 CT reconstructions were evaluated by three independent readers. Reviewers determined the presence of foreign bodies and evaluated the image quality using a 5-point ranking scale. In addition, visualization of incidental findings was assessed.

RESULTS

A threshold of 5% (effective dose 0.11 ± 0.07 mSv) was necessary to correctly identify all 27 patients with suspected body packing. Extensive noise insertion to a dose level of 1% (0.02 ± 0.01 mSV) led to false-positive solid cocaine findings in three patients. Image quality was comparable between 100 and 50%. The threshold for correct identification of incidental findings was 10% of the initial dose (effective dose 0.21 ± 0.13 mSv).

CONCLUSIONS

Our results indicate that dose of abdominal CT for the detection of intracorporeal cocaine body packets can be markedly reduced to up to 5% of the initial dose while still providing sufficient image quality to detect ingested body packets. However, a minimum effective dose of 0.21 mSv (10% of initial dose) seems to be required to properly identify incidental findings.

Для цитирования: Aissa Joel, Bölke Edwin, Sawicki Lino M, Appel Elisabeth, Thomas Christoph, Heusch Philipp, Sedlmair Martin, Krzymyk Karl, Kröpil Patric, Antoch Gerald, Boos Johannes. Noise insertion in CT for cocaine body packing: where is the limit of extensive dose reduction?. European journal of medical research. 2018. DOI: 10.1186/s40001-018-0356-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.