MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjsurg.2009.05.017

Медицинская библиотека · American journal of surgery · 2010

Analysis of anatomic variants of mesenteric veins by 3-dimensional portography using multidetector-row computed tomography.

Sakaguchi Takanori, Suzuki Shohachi, Morita Yoshifumi, Oishi Kosuke, Suzuki Atsushi, Fukumoto Kazuhiko, Inaba Keisuke, Kamiya Kinji, Ota Manabu, Setoguchi Tomohiko, Takehara Yasuo, Nasu Hatsuko, Nakamura Satoshi, Konno Hiroyuki

СтатьяПеревод в очереди

Аннотация

BACKGROUND

It is important to be aware of mesenteric venous variants to perform peripancreatic surgery. We investigated the usefulness of 3-dimensional (3-D) portography.

METHODS

Vessels were reconstructed using computer software in 102 patients undergoing multidetector-row computed tomography (MDCT) scheduled for gastrointestinal or hepatobiliary-pancreatic surgery.

RESULTS

The superior mesenteric vein (SMV) was composed of single and double trunks around the splenoportal confluence in 78 and 24 patients, respectively. The inferior mesenteric vein joined the splenic vein (68.5%), SMV (18.5%), and splenoportal confluence (7.6%). The left gastric vein joined the splenic vein (46.3%), portal vein (39.0%), and splenoportal confluence (14.7%). Seventy-nine patients showed a gastrocolic trunk, mostly composed of the right gastroepiploic vein and veins from the colonic hepatic flexure. Intraoperative findings were identical to 3-D diagnosis in 68 gastrectomized and 9 pancreatectomized patients.

CONCLUSION

Although mesenteric venous tributaries are complex, 3-D portography is helpful for surgeons to safely perform peripancreatic surgery.

Для цитирования: Sakaguchi Takanori, Suzuki Shohachi, Morita Yoshifumi, Oishi Kosuke, Suzuki Atsushi, Fukumoto Kazuhiko, Inaba Keisuke, Kamiya Kinji, Ota Manabu, Setoguchi Tomohiko, Takehara Yasuo, Nasu Hatsuko, Nakamura Satoshi, Konno Hiroyuki. Analysis of anatomic variants of mesenteric veins by 3-dimensional portography using multidetector-row computed tomography.. American journal of surgery. 2010. DOI: 10.1016/j.amjsurg.2009.05.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.