MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carpath.2018.05.002

Медицинская библиотека · Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology · 2018

Method for preclinical pathology evaluation and analysis of cardiovascular implantable electronic device implant sites.

Jessen Staci L, O'Brien Maureen T, Lancon Trevor W, Smith Harrison R, Suarez Leslie L, Wilcox Matthew D, Miller Matthew, Weeks Brad R, Clubb Fred J

СтатьяПеревод в очереди

Аннотация

UNLABELLED: Cardiovascular implantable electronic devices (CIEDs) typically incorporate leads that directly contact the endocardium. Post-explant pathology evaluation of formalin-fixed CIED lead implant sites and downstream organs (i.e., lungs) can provide useful safety data to the US Food and Drug Administration; however, current regulatory guidelines do not mandate how the safety data are collected. In this paper, we outline a protocol for preclinical pathology evaluation of leads associated with CIEDs, which includes formalin fixation of the heart and lungs, gross evaluation, and qualitative and quantitative histologic evaluation. We recommend fixation of the whole heart with leads in situ alongside intratracheal formalin infusion; this enables rapid and effective preservation of target tissues and increases histologic quality to allow for accurate qualitative and quantitative pathology evaluation. Overall, we believe that our approach to pathology evaluation of leads may maximize information acquired from preclinical studies, leading to more accurate safety assessments.

SUMMARY: This article introduces an established method for pathology evaluation and analysis of cardiac leads recommended for companies and researchers that seek approval from a regulatory body.

Для цитирования: Jessen Staci L, O'Brien Maureen T, Lancon Trevor W, Smith Harrison R, Suarez Leslie L, Wilcox Matthew D, Miller Matthew, Weeks Brad R, Clubb Fred J. Method for preclinical pathology evaluation and analysis of cardiovascular implantable electronic device implant sites.. Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology. 2018. DOI: 10.1016/j.carpath.2018.05.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.