The monitoring of pollutants has received significant attention from researchers in recent years owing to their hazardous nature and their toxic effect on the environment. Among them, water pollution plays a major role and results in dominant diseases along with life-long health problems. Hydroquinone (HQ), the major metabolite of benzene, is an industrially used organic compound which causes symptoms associated with nervous related disorders, such as faintness, therefore the research community has been inspired to detect sources of this carcinogenic agent. In this work, cobalt-iron based zeolitic imidazolate framework microfibers (CoFe-ZIF-MFs) were used for the selective detection of HQ. Micro-structured CoFe-ZIF fibers were fabricated using the wet chemical and electrospinning method. The electrochemical response of the prepared composite revealed an excellent redox behavior towards HQ and does not suffer from interference resulting from other analytes. The proposed sensor exhibited a wide linear range of 1 μM-1 mM with a detection limit of 230 nM, resulting in a good stability of up to 88%, even after 250 cycles. The designed sensor showed an exquisite performance for real sample analysis which indicates the device mechanism is reliable for use in environmental monitoring, public health care, industrialized areas and waste water management systems.

Для цитирования: Thenrajan Thatchanamoorthy, Sam Sankar Selvasundarsekar, Srinivasan Girija, Kundu Subrata, Wilson Jeyaraj. Cobalt-iron zeolitic imidazolate frameworks (ZIFs) as microfibers for the effective detection of hydroquinone.. Dalton transactions (Cambridge, England : 2003). 2021. DOI: 10.1039/d1dt01718g.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.