m+Medelevator.RU
← Поиск публикаций
Journal of thrombosis and thrombolysis · 2024

Intraoperative haemoadsorption for antithrombotic drug removal during cardiac surgery: initial report of the international safe and timely antithrombotic removal (STAR) registry.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schmoeckel Michael, Thielmann Matthias, Hassan Kambiz, Geidel Stephan, Schmitto Jan, Meyer Anna L, Vitanova Keti, Liebold Andreas, Marczin Nandor, Bernardi Martin H, Tandler Rene, Lindstedt Sandra, Matejic-Spasic Marijana, Wendt Daniel, Deliargyris Efthymios N, Storey Robert F

Аннотация

Intraoperative antithrombotic drug removal by haemoadsorption is a novel strategy to reduce perioperative bleeding in patients on antithrombotic drugs undergoing cardiac surgery. The international STAR registry reports real-world clinical outcomes associated with this application. All patients underwent cardiac surgery before completing the recommended washout period. The haemoadsorption device was incorporated into the cardiopulmonary bypass (CPB) circuit. Patients on P2Y12 inhibitors comprised group 1, and patients on direct-acting oral anticoagulants (DOAC) group 2. Outcome measurements included bleeding events according to standardised definitions and 24-hour chest-tube-drainage (CTD). 165 patients were included from 8 institutions in Austria, Germany, Sweden, and the UK. Group 1 included 114 patients (62.9 ± 11.6years, 81% male) operated at a mean time of 33.2 h from the last P2Y12 inhibitor dose with a mean CPB duration of 117.1 ± 62.0 min. Group 2 included 51 patients (68.4 ± 9.4years, 53% male), operated at a mean time of 44.6 h after the last DOAC dose, with a CPB duration of 128.6 ± 48.4 min. In Group 1, 15 patients experienced a BARC-4 bleeding event (13%), including 3 reoperations (2.6%). The mean 24-hour CTD was 651 ± 407mL. In Group 2, 8 patients experienced a BARC-4 bleeding event (16%) including 4 reoperations (7.8%). The mean CTD was 675 ± 363mL. This initial report of the ongoing STAR registry shows that the intraoperative use of a haemoadsorption device is simple and safe, and may potentially mitigate the expected high bleeding risk of patients on antithrombotic drugs undergoing cardiac surgery before completion of the recommended washout period.Clinical registration number: ClinicalTrials.gov identifier: NCT05077124.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты