m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. A · 2024

Two-dimensional metal-organic framework nanosheets coated solid-phase microextraction Arrow coupled with UPLC-Q-ToF-MS for the determination of three veterinary residues in milk and pork.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Du Xuanhua, Lan Hangzhen, Wu Zhen, Pan Daodong, Wu Yichun

Аннотация

This study presents a method utilizing solid-phase microextraction Arrow (SPME Arrow) combined with ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) for the selective detection of three veterinary drugs-thiabendazole, sulfamethazine, and clenbuterol-in milk and pork. Two-dimensional metal-organic framework nanosheets (2D-MOFs) were employed as coating materials for the SPME Arrow. Three types of 2D-MOFs (Ni, Mn, and Co based) were synthesized and characterized using Fourier transform infrared spectroscopy, scanning electron microscopy, transmission electron microscopy, and a physical adsorption analyzer. The 2D-MOF coatings were fabricated using the electrospinning technique, with polyacrylonitrile (PAN) serving as the binder. Comparative analysis of the three 2D-MOF coatings revealed that 2D-Ni-MOF was the optimal coating material for the SPME Arrow. Optimization of the coating preparation conditions and SPME procedures included determining the optimal mass ratio of 2D-Ni-MOF to PAN, electrospinning time, and extraction and desorption parameters. Equilibrium extraction was achieved within 60 min, and desorption was completed within 30 min. Subsequently, the 2D-Ni-MOF-SPME Arrow-UPLC-Q-TOF-MS method was established and validated under optimal conditions, demonstrating high precision with inter-day precision ranging from 3.8 % to 9.5 % and intra-day precision ranging from 5.1 % to 11.5 %. The reusability study indicated that the extraction performance of the new SPME Arrow remained consistent after 90 adsorption-desorption cycles. The method exhibited linearity in milk and pork over the ranges of 0.002-5 μg L-1 and 0.01-5 μg L-1, respectively. The detection limits in milk and pork were 0.001-0.004 μg L-1 and 0.003-0.007 μg L-1, respectively. This method demonstrated excellent applicability for determining residues of the three veterinary drugs in milk and pork.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты