Circulation. Heart failure · 2019

Effect of Continuous-Flow Left Ventricular Assist Device Support on Coronary Artery Endothelial Function in Ischemic and Nonischemic Cardiomyopathy.

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Symons J David, Deeter Lance, Deeter Nicholas, Bonn Trevor, Cho Jae Min, Ferrin Peter, McCreath Lauren, Diakos Nikolaos A, Taleb Iosif, Alharethi Rami, McKellar Stephen, Wever-Pinzon Omar, Navankasattusas Sutip, Selzman Craig H, Fang James C, Drakos Stavros G

Аннотация

BACKGROUND: The coronary vasculature encounters a reduction in pulsatility after implementing durable continuous-flow left ventricular assist device (CF-LVAD) circulatory support. Evidence exists that appropriate pulsatility is required to maintain endothelial cell homeostasis. We hypothesized that coronary artery endothelial function would be impaired after CF-LVAD intervention.

METHODS AND RESULTS: Coronary arteries from patients with end-stage heart failure caused by ischemic cardiomyopathy (ICM; n=16) or non-ICM (n=22) cardiomyopathy were isolated from the left ventricular apical core, which was removed for the CF-LVAD implantation. In 11 of these patients, paired coronary arteries were obtained from an adjacent region of myocardium after the CF-LVAD intervention (n=6 ICM, 5 non-ICM). Vascular function was assessed ex vivo using isometric tension procedures in these patients and in 7 nonfailing donor controls. Maximal endothelium-dependent vasorelaxation to BK (bradykinin; 10-6-10-10 M) was blunted (P<0.05) in arteries from patients with ICM compared with non-ICM and donor controls, whereas responses to sodium nitroprusside (10-4-10-9 M) were similar among the groups. Contrary to our hypothesis, vasorelaxation responses to BK and sodium nitroprusside were similar before and 219±37 days after CF-LVAD support. Of these patients, an exploratory subgroup analysis revealed that BK-induced coronary artery vasorelaxation was greater (P<0.05) after (87±6%) versus before (54±14%) CF-LVAD intervention in ICM patients, whereas sodium nitroprusside-evoked responses were similar.

CONCLUSIONS: Coronary artery endothelial function is not impaired by durable CF-LVAD support and in ICM patients appears to be improved. Investigating coronary endothelial function using in vivo approaches in a larger patient population is warranted.